12   CONTROL SUB FUNCTIONS 
 
12.7 Other functions 
Other functions include the "step function", "skip function", "M code output function", 
"teaching function", "command in-position function", "acceleration/deceleration 
processing function", "pre-reading start function", "deceleration start flag function" and 
"stop command processing for deceleration stop function". Each function is executed 
by parameter setting or sequence program creation and writing.   
 
12.7.1 Step function 
The "step function" is used to confirm each operation of the positioning control one by 
one.  
It is used in debugging work for major positioning control, etc. 
A positioning operation in which a "step function" is used is called a "step operation".   
In step operations, the timing for stopping the control can be set. (This is called the 
"step mode".) Control stopped by a step operation can be continued by setting "step 
continue" (to continue the control)" in the "step start information".   
 
The details shown below explain about the "step function".   
    [1] Relation between the step function and various controls 
  [2] Step mode 
  [3] Step start information 
    [4] Using the step operation   
  [5] Control details 
  [6] Control precautions 
  [7] Setting method 
 
[1]      Relation between the step function and various controls 
The following table shows the relation between the "step function" and various 
controls. 
 
Control type 
Step function
Step applicability 
OPR control 
Machine OPR control 
Step operation not possible
Fast OPR control 
Major 
positioning 
control 
Position 
control 
1-axis linear control 
Step operation possible 
2- to 4-axis linear interpolation control 
1-axis fixed-feed control 
2- to 4-axis fixed-feed control 
(interpolation) 
 
2-axis circular interpolation control 
1- to 4-axis Speed control 
Step operation not possible
Speed-position switching control 
Position-speed switching control 
 
Step operation possible 
Other 
control 
Current value changing 
JUMP instruction, NOP instruction, 
LOOP to LEND 
 
Step operation not possible
Manual 
control 
JOG operation, Inching operation 
Step operation not possible
Manual pulse generator operation 
 
                             
  : Set when required. 
  : Setting not possible