Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
5 - 74
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL
5.4 List of block start data
The illustrations below show the organization of the block start data stored in the QD75
buffer memory. The block start data setting items 
Da.11
to
Da.14
are explained in
the pages that follow.
Setting item
Buffer memory
address
26049
26099
œ ˆÊ ’u Œ
ˆ
‚ß n “® ƒ
f [ ƒ
^
26001
26051
b15
b0
b7
b8
Da.11 Shape
Da.12 Start data No.
26000
b15
b0
b7
b8
Da.13 Special start
           instruction
Da.14 Parameter
26050
Buffer memory
address
Buffer memory
address
Setting item
Setting item
1st point
2nd point
50th point
A
x
is
 1 (S
ta
rt
 bl
o
c
k 0
)
27049
27099
27001
27051
œ ˆÊ ’u Œ
ˆ
‚ß n “® ƒ
f [ ƒ
^
b15
b0
b7
b8
Da.11 Shape
Da.12 Start data No.
27000
b15
b0
b7
b8
Da.13 Special start
           instruction
Da.14 Parameter
27050
Setting item
Buffer memory
address
Buffer memory
address
Buffer memory
address
Setting item
Setting item
1st point
2nd point
50th point
A
x
is
 2 (S
ta
rt
 bl
o
c
k 0
)
Up to 50 block start data points can be set
(stored) for each axis in the buffer memory
addresses shown on the left.
Items in a single unit of block start data are
shown included in a bold frame.
Each axis has five start blocks (block Nos.
0 to 4).
For information on the organization of the
buffer memory addresses assigned to the
start blocks 1 to 4, refer to Appendix 12
 "List of buffer memory addresses".