Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
5 - 85
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL
Da.18
Parameter 1
Set the parameters as required for the "
Da.16
Condition operator".
Da.16 Condition operator
Setting value
Setting details
01
H
 :
∗∗
=P1
02
H
 :
∗∗≠
P1
03
H
 :
∗∗≤
P1
04
H
 :
∗∗≥
P1
05
H
  : P1
≤∗∗≤
P2
06
H
 : 
∗∗≤
P1, P2
≤∗∗
Value
The value of P1 should be equal to or smaller than the value of
P2. (P1
P2)
If P1 is greater than P2 (P1>P2), the "condition data error" (error
code 533) will occur.
07
H
 : DEV=ON
08
H
 : DEV=OFF
Value
(bit No.)
Set the device bit No.
X:  0
H
 to 1
H
, 4
H
 to 11
H
 Y:  0, 4
H
 to 17
H
10
H
 : Axis 1 selected
 
E0
H
 : Axes 2, 3, and 4 selected
Value
(positioning data No.)
Set the positioning data No. for starting axis 1 and/or axis 2.
Low-order 16-bit
:  Axis 1 positioning data No. 1 to 600 (01
H
 to 258
H
)
High-order 16-bit
:  Axis 2 positioning data No. 1 to 600 (01
H
 to 258
H
)
Da.19
Parameter 2
Set the parameters as required for the "
Da.16
Condition operator".
Da.16 Condition operator
Setting value
Setting details
01
H
 : 
∗∗
=P1
02
H
 :
∗∗≠
P1
03
H
 :
∗∗≤
P1
04
H
 :
∗∗≥
P1
Not used.  (No need to be set.)
05
H
  : P1
≤∗∗≤
P2
06
H
 :
∗∗≤
P1, P2
≤∗∗
Value
The value of P2 should be equal to or greater than the value of
P1. (P1
P2)
If P1 is greater than P2 (P1>P2), the "condition data error" (error
code 533) will occur.
07
H
 : DEV=ON
08
H
 : DEV=OFF
10
H
 : Axis 1 selected
20
H
 : Axis 2 selected
30
H
 : Axes 1 and 2 selected
Not used.  (No need to be set.)
40
H
 : Axis 3 selected
50
H
 : Axes 1 and 3 selected
60
H
 : Axes 2 and 3 selected
70
H
 : Axes 1, 2, and 3 selected
80
H
 : Axis 4 selected
90
H
 : Axes 1 and 4 selected
A0
H
 : Axes 2 and 4 selected
B0
H
 : Axes 1, 2, and 4 selected
C0
H
 : Axes 3 and 4 selected
D0
H
 : Axes 1, 3, and 4 selected
E0
H
 : Axes 2, 3, and 4 selected
Value
(positioning data No.)
Set the positioning data No. for starting axis 3 and/or axis 4.
Low-order 16-bit
:  Axis 3 positioning data No. 1 to 600 (01
H
 to 258
H
)
High-order 16-bit
:  Axis 4 positioning data No. 1 to 600 (01
H
 to 258
H
)