11   MANUAL CONTROL
 Inching operation timing and processing times
The following drawing shows the details of the inching operation timing and
processing time.
Reverse run JOG start signal
[Y9,YB,YD,YF]
BUSY signal
[XC,XD,XE,XF]
Forward run JOG start signal
[Y8,YA,YC,YE]
ON
Standing by
Inching operation
Axis operation
status
t1
t2
t4
Pulse output to an external
source
(PULSE)
Positioning operation
Positioning complete
signal
[X14,X15,X16,X17]
Md.26
ON
ON
OFF
OFF
OFF
OFF
t3
Standing by
Fig. 11.13 Inching operation timing and processing times
Normal timing times                                           Unit : ms
t1
t2
t3
t4
1.0 to 3.0
2.7 to 4.4
0 to 1.8
Depending on
parameters
 Depending on the operating statuses of the other axes, delay may occur in the
t1 timing time.