Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
14 - 5
MELSEC-Q
14   DEDICATED INSTRUCTIONS
(2) An I/O module is used for communication (data read/write) with the servo amplifier
capable of processing the absolute positions.
When using the ABRST , prepare the input/output with the following number of
points, for each axis, for communication with the servo amplifier.
  • Input :
3 points
  • Output : 
3 points
Refer to Section 12.6 for wiring of I/O signals.
(3) The ABRST  instruction completion can be confirmed using the complete devices
((D)+0) and ((D)+1).
(a) Complete device ((D)+0)
This device is turned ON by the END processing of the scan for which
ABRST  instruction is completed, and turned OFF by the next END
processing.
(b) Complete state display device ((D)+1)
This device is turned ON and OFF according to the state in which ABRST
instruction is completed.
  • When completed normally
:Kept unchanged at OFF.
  • When completed abnormally:This device is turned ON by the END
processing of the scan for which ABRST
instruction is completed, and turned OFF by
the next END processing. (same ON/OFF
operation as complete device).
END 
processing
END 
processing
END 
processing
END 
processing
OFF
OFF
OFF
ON
ON
ON
When 
completed 
abnormally
When 
completed normally
1 scan
ABRST    instruction
execution completion
Sequence program
ABRST    instruction
Complete device
Complete state display 
device
The completion of absolute position restoration can be confirmed using the ((S)+4)
"status".