Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
14 - 10
MELSEC-Q
14   DEDICATED INSTRUCTIONS
END 
processing
END 
processing
END 
processing
END 
processing
OFF
OFF
OFF
ON
ON
ON
When 
completed 
abnormally
When 
completed normally
1 scan
PSTRT    instruction
execution completion
Sequence program
PSTRT    instruction
Complete device
Complete state display 
device
[Errors]
(1) When an PSTRT  instruction is completed abnormally, the error complete signal
((D)+1) is turned ON, and the error code is stored in the complete status ((S)+1).
Check and take a measure against the error referring to Section 15.2 "List of error
codes".
[Precautions]
(1) When positioning is started by the PSTRT  instruction, the positioning start
signals (Y10 to Y13) and start complete signals (X10 to X13) will not turn ON.
To confirm that positioning control is being executed, use the PSTRT  start
command or BUSY signals (XC to XF).
(2) If, after positioning has been started by the PSTRT  instruction, a stop command
is input before positioning is complete, the complete device (D) turns ON one scan
and the execution of the PSTRT  instruction is completed.
(3) The following dedicated instructions cannot be executed simultaneously for the
same axis.
(Can be executed simultaneously for different axes.)
  • Positioning start instructions (PSTRT1 to PSTRT4)
  • Absolute position restoration instructions (ABRST1 to ABRST4)
  • Teaching instructions (TEACH1 to TEACH4)
(4) The PSTRT  instruction can only be executed when the QD75 READY signal
(X0) is turned ON.
Even if the PSTRT  instruction execution request is given when the QD75
READY signal is turned OFF, the PSTRT  instruction will not be executed. (not
processed.)
Before executing the PSTRT  instruction, turn ON the PLC READY signal (Y0),
and turn ON the QD75 READY signal (X0).
(5) When the remote I/O station  (Q Corresponding MELSECNET/H network remote
I/O module) is used, the dedicated instruction (PSTRT ) is unusable.
: For details of the remote I/O station, refer to Q Corresponding MELSECNET/H
Network System Reference Manual (Remote I/O Network).