Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
15 - 31
MELSEC-Q
15   TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with sequence program)
Remedy
71
221
371
521
0, 1
72
73
222
223
372
373
522
523
• [mm] [inch] [pulse]
–2147483648 to 2147483647
• [degree] 0 to 35999999
With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.
74
75
224
225
374
375
524
525
1 to 1000000 [pulse/s]
1 to 2000000000 [mm/min or others]
• Bring the setting into the setting range.
• Set the speed to the bias speed at start or higher.
(Refer to Section 5.2.5)
76
77
226
227
376
377
526
527
1 to 1000000 [pulse/s]
1 to 2000000000 [mm/min or others]
• Bring the setting into the setting range.
• Set the speed to that below the OPR speed.
• Set the value to the bias speed at start or higher.
(Refer to Section 5.2.5)
78
228
378
528
0, 1
79
229
379
529
0 to 65535
80
81
230
231
380
381
530
531
0 to 2147483647
82
232
382
532
0, 1, 2, 3
83
233
383
533
0, 1, 2, 3
86
236
386
536
1 to 300
87
237
387
537
1 to 65535
88
238
388
538
0, 1
With the setting brought into the setting range, turn the
PLC READY signal [Y0] from OFF to ON.