Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
Appendix - 43
MELSEC-Q
APPENDICES
Appendix 8 Connection examples with servo amplifiers manufactured by YASKAWA Electric
Corporation
Appendix 8.1 Connection example of QD75D  and 
-  series (Differential driver)
4
PULSE F+
PULSE R+
CLEAR
CLEAR COM
READY
PULSER A+
PULSER A-
PULSER B+
PULSER B-
B19
A20
B20
DOG
FLS
RLS
STOP
CHG
COM
COM
3
1
2
4
5
15
16
17
18
14
9
24G
P24V
  3
2m max
PULS
  5
5V
A
B
0V
+5V
5G
2
MR-HDP01
  1
PULSE F-
PULSE R-
RDY COM
10
PGO5
PGO COM
13
11
12
A19
6
7
/PULS
SIGN
/SIGN
/CLR
PCO
/PCO
S-RDY+
S-RDY-
S-ON
8
11
12
14
1
20
29
30
15 CLR
PL3
18
40
42
SG
19
P-OT
N-OT
43
47
QD75D
7
+24VIN
2
Manual pulse 
generator
Near-point dog
Upper limit   2
Lower limit   2
Stop
External command
REMARK
(1)  1: The logic of each I/O terminal can be changed with "
 Pr.22 
 Input signal logic selection" and "
 Pr.23 
 Output signal
logic selection" in detailed parameters 1. (Negative logic is used for all terminals in the example above.)
(2)  2: The QD75D
 
 upper limit (FLS) and lower limit (RLS) are used in the OPR retry function. Set these signals
inside the servo amplifier limit switches.
(3)  3: Refer to the manual of the servo amplifier for information on the servo amplifier side wiring and various signal
wire shields not shown above.
(4)  4: Use the same logic (positive logic/negative logic) for the QD75D
 
 and servo amplifier. The QD75D
 
 is
initially set to negative logic.
(5)  5: This indicates the distance between the QD75D  and 
- .