Справочник Пользователя для Mitsubishi Electronics QD75D1N
9 - 5
MELSEC-Q
9 MAJOR POSITIONING CONTROL
9.1.2 Operation patterns of major positioning controls
In "major positioning control" (high-level positioning control), " Da.1 Operation
pattern" can be set to designate whether to continue executing positioning data after
the started positioning data. The "operation pattern" includes the following 3 types.
pattern" can be set to designate whether to continue executing positioning data after
the started positioning data. The "operation pattern" includes the following 3 types.
Positioning complete
(1) Independent positioning control
(operation pattern: 00)
(operation pattern: 00)
Positioning continue
(2) Continuous positioning control
(operation pattern: 01)
(3) Continuous path control
(operation pattern: 11)
(operation pattern: 01)
(3) Continuous path control
(operation pattern: 11)
The following shows examples of operation patterns when "1-axis linear control (ABS
linear 1)" is set in positioning data No. 1 to No. 6 of axis 1. Details of each operation
pattern are shown on the following pages.
linear 1)" is set in positioning data No. 1 to No. 6 of axis 1. Details of each operation
pattern are shown on the following pages.
< Operation example when "1-axis linear positioning" is set in the positioning data of axis 1 >
(Direction in which axis 1 addresses increase)
1-axis linear control
(One motor is driven, and positioning is carried out to an addresses designated in one direction.)
Speed
Positioning data No.1
0
Operation pattern = 11: Continuous path control
Positioning to address [A] at command speed [a]
No.2
No.3
No.4
No.5
Address
a
b
NO.1
No.2
No.3
No.4
No.5
Speed is changed
without stopping
without stopping
The machine stops, and
then continues the next
positioning.
Positioning is terminated
No.6
Control stop
No.1 Start
11
11
01
01
00
Time
Da. 1 Operation pattern
(Positioning data)
(Setting details)
Positioning to address [C] at command speed [a]
Positioning to address [D] at command speed [b]
Positioning to address [E] at command speed [a]
Positioning to address [F] at command speed [a]
Positioning to address [B] at command speed [b]
Operation pattern = 11: Continuous path control
Operation pattern = 01:
Continuous positioning control
Operation pattern = 00: Independent positioning control
(Positioning complete)
(Positioning complete)
Operation pattern = 11: Continuous path control
Operation pattern = 01:
Continuous positioning control
A
E
D
C
B
F
For
POINT
The BUSY signal [XC, XD, XE, XF] turns ON even when position control of
movement amount 0 is executed. However, since the ON time is short, the ON
status may not be detected in the sequence program.
movement amount 0 is executed. However, since the ON time is short, the ON
status may not be detected in the sequence program.