15   TROUBLESHOOTING 
 
 
15.4 List of warnings 
The following table shows the warning details and remedies to be taken when a 
warning occurs. 
 
Classification 
of warnings 
Warning 
code 
Warning name 
Warning 
Operation status at warning 
occurrence 
 
 
 
— 000 
(Normal 
status) 
— 
— 
 
Common 
100 
Start during 
operation 
The start request is issued while the 
axis is BUSY. 
Continue the operation. 
 
102 
Deviation counter 
clear request 
The deviation counter clear request 
is issued while the axis is BUSY. 
The deviation counter clear request is 
ignored. 
 
104  Restart not possible 
The restart command is issued when 
the axis operation status is not 
"Stopped". 
Continue the operation. 
 
 
 
 
109  Teaching in BUSY 
The teaching request is issued while 
the axis is BUSY. 
The warning is issued for the axis 
designated at the time of the teaching 
request. 
 
 
 
 
110 
Less than minimum 
speed 
The overridden speed becomes “0”.
The system is controlled with the 
currently executing unit of 1. 
 
 
 
111  In PLC READY 
The request for writing to the flash 
ROM is issued when the PLC 
READY is turned ON. 
The warning for axis 1 is issued. 
 
 
 
 
 
112 
Illegal override 
value 
A value other than 1 to 300 is set for 
the override value. 
• Controlled at a setting value of   
0 : 100. 
• Controlled at a setting value of   
301 or over : 300. 
 
 
 
 
113 
Outside new torque 
value range 
The new torque value exceeds the 
torque limit setting value. 
Set a value smaller than the torque 
limit setting value to the new torque 
value. 
 
 
 
 
114  Below bias speed 
The command speed is below the 
bias speed at start. 
Operate by the bias speed at start.