Appendix 10.10 External I/O signal logic switching function 
This function switches the signal logic according to the external equipment connected 
to the QD75. 
For the system in which drive unit READY with b-contact, upper limit switch, and lower 
limit switch are not used, the parameter logic setting can be controlled without wiring if 
it is changed to a "positive logic". 
When the drive unit READY, upper limit switch, and lower limit switch are used, ensure 
to use them with b-contact. 
 
The details shown below explain about the "external I/O signal logic switching function". 
  [1] Parameter setting details 
  [2] Precautions on parameter setting 
 
[1]  Parameter setting details 
To use the "external I/O signal logic switching function", set the parameters 
shown in the following table. 
 
Setting item 
Setting details 
Factory-set 
initial value 
Buffer memory address 
Axis 1  Axis 2  Axis 3 Axis 4
 Pr.22  
Input signal logic 
selection 
• Selection of logic of signals input from external source to 
QD75 
0 31 
181 
331
481
 b0 
Lower 
limit 
0: Negative logic, 
1: Positive logic 
 b1 
Upper 
limit 
 b2 
Drive unit 
READY 
 b3 
Stop 
signal 
 b4 
External 
command signal
 b5 
Zero 
signal 
 b6 
Near-point dog 
signal 
 b7 
Unused 
Set 
"0". 
 b8 
Manual pulse 
generator input 
0: Negative logic, 
1: Positive logic 
 
b9 to b15 
Unused 
Set "0". 
 Pr.23  
Output signal logic 
selection 
• Selection of logic of signals output from QD75 to external 
source 
0 32 
182 
332
482
 b0 
Command pulse 
signal 
0: Negative logic, 
1: Positive logic 
 
b1 to b3 
Unused 
Set "0". 
 b4 
Deviation counter 
clear signal 
0: Negative logic, 
1: Positive logic 
 
b5 to b15 
Unused 
Set "0". 
  Refer to Section 5.2 "List of parameters" for the information on detail settings. 
 
[2]   Precautions on parameter setting 
(1)    The external I/O signal logic switching parameters are validated when the 
PLC READY signal [Y0] is turned OFF to ON. (The logic is negative right 
after power-on.) 
 
(2)    If each signal logic is set erroneously, the operation may not be carried out 
correctly. 
Before setting, check the specifications of the equipment to be used.