SECTION 3: 
MODES OF OPERATION 
3.1 
MODES OF OPERATION 
There are two modes of operation when using the HEGS5000 as a standalone controller: 
1.  HEGS5000 = Standalone = PTZ control (KD6/HD6 and KDZ series) only.  Note:  
KDZ series domes have been discontinued. 
2.  HEGS5001 = MUX Mode = MUX/VCR control capability and PTZ control 
There is a third mode of operation that is only for use with the HSX3208L Matrix Video 
Switcher. 
3.  HEGS5002 = System = HSX3208L Switcher.  Refer to the HSX3208L Switcher User 
Manual for setup and operation of the HEGS5000 in System mode. 
The default configuration is Standalone  mode (PTZ control only).  To change the 
configuration, refer to Section 3.2 
3.2 MODE 
CONFIGURATION 
To configure the HEGS5000 mode of operation, perform the following steps. 
1.  Power-up the HEGS5000.  The following messages are displayed on the LCD 
display. 
519685-1980  A 
   Booting in 5s 
Boot Mngr MMDDYY 
 
 
 
 
2.  Before the unit counts down to 0, press 1.  The LCD displays: 
** Standalone ** 
<   Run Bank   > 
 
 
 
Note:  The current configuration is displayed with ** on both sides as shown above. 