Справочник Пользователя для Mitsubishi Electronics FX2NC

Скачать
Страница из 382
FX Series Programmable Controlers
Applied Instructions 5
5-47
5.5.7
ANS (FNC 46)
Operation:
This instruction, when energized, starts a timer (S)
for n,100 msec. When the timer completes its cycle
the assigned annunciator (D) is set ON.
If the instruction is switched OFF during or after completion of the timing cycle the timer is
automatically reset. However, the current status of the annunciator coil remains unchanged.
5.5.8
ANR (FNC 47)
Operation:
Annunciators which have been activated are
sequentially reset one-by-one, each time the ANR
instruction is operated.
If the ANR instruction is driven continuously it will carry out its resetting operation on every
program scan unless it is modified by the pulse, P prefix or by a user defined program
interlock.
Mnemonic
Function 
Operands
Program steps
S
D
n
ANS
FNC 46
(Timed
annunciator 
set)
This instruction
starts a timer.
Once timed out
the selected
annunciator flag is
set ON
T
Note:
available 
range
T0 to T199
S
Note:
annunciator
range S900 to 
S999
K
Note:
n range 1 to
32,767 - in 
units of 
100msec
ANS:
7 steps
Mnemonic
Function 
Operands
Program steps
D
ANR
FNC 47
(
Annunciator 
reset)
The lowest active
annunciator is
reset on every
operation of this
instruction
N/A 
ANR,ANRP:
1step
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)
FX
(2C)
FX
FX
2N(C)
FX
0N
FX
0(s)
PULSE-P
FX
(2C)
FX
FX
2N(C)
FX
0N
FX
0(s)
16 BIT OPERATION
FX
FX
0N
FX
0(s)
FX
(2C)
FX
2N(C)
32 BIT OPERATION
X0
K 10 S900
[ S ]
[ D ]
T 0
ANS
[ n ]
X1
Note: This is only one method of driving annunciator coils, others such as direct setting can
also be used.
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)
FX
(2C)
FX
FX
2N(C)
FX
0N
FX
0(s)
PULSE-P
FX
(2C)
FX
FX
2N(C)
FX
0N
FX
0(s)
16 BIT OPERATION
FX
FX
0N
FX
0(s)
FX
(2C)
FX
2N(C)
32 BIT OPERATION
X3
ANR