Справочник Пользователя для Mitsubishi Electronics FX2NC
FX Series Programmable Controlers
Applied Instructions 5
5-94
5.9
External FX Serial Devices - Functions 80 to 89
Contents:
Page
RS -
RS Communications
FNC 80
5-95
PRUN -
FX
2
-40AP Parallel Run
FNC 81
5-96
ASCI -
Hexadecimal to ASCII
FNC 82
5-98
HEX -
ASCII to Hexadecimal
FNC 83
5-99
CCD -
Check Code
FNC 84
5-100
VRRD -
FX-8AV Volume Read
FNC 85
5-101
VRSC -
FX-8AV Volume Scale
FNC 86
5-101
-
Not Available
FNC 87
PID -
PID Control Loop
FNC 88
5-102
-
Not Available
FNC 89
Symbols list:
D - Destination device.
S - Source device.
m, n- Number of active devices, bits or an operational constant.
Additional numeric suffixes will be attached if there are more than one operand with the same
function e.g. D
S - Source device.
m, n- Number of active devices, bits or an operational constant.
Additional numeric suffixes will be attached if there are more than one operand with the same
function e.g. D
1
, S
3
or for lists/tabled devices D
3+0,
S
+9
etc.
MSB - Most Significant Bit, sometimes used to indicate the mathematical sign of a number, i.e.
positive = 0, and negative = 1.
LSB - Least Significant Bit.
positive = 0, and negative = 1.
LSB - Least Significant Bit.
Instruction modifications:
-
An instruction operating in 16 bit mode, where
identifies the instruction
mnemonic.
P - A 16 bit mode instruction modified to use pulse (single) operation.
D
- An instruction modified to operate in 32 bit operation.
D
P - A 32 bit mode instruction modified to use pulse (single) operation.
- A repetitive instruction which will change the destination value on every scan unless
modified by the pulse function.
- An operand which cannot be indexed, i.e. The addition of V or Z is either invalid or will
have no effect to the value of the operand.