FX Series Programmable Controllers
Devices in Detail 4
4-19
4.10
Counters
Device Mnemonic: C
Purpose: Event driven delays
Alias: Counter(s)
C
Available forms: A  driven coil sets internal PLC contacts (NO and NC contacts available).
Various counter resolutions are possible including;
General/latched 16bit up counters - see page 4-20
General/latched 32bit bi-directional counters - see page 4-21
(The availability and use of all these counters is PLC specific - please
check availability before use)
Devices numbered in: Decimal, i.e C0 to C9, C10 to C19
Further uses: None
Example device usage:
Available devices:
High speed counters:
For high speed counters please see page 4-22.
Setting ranges for counters:
16bit counters: -32,768 to +32,767
32bit counters: -2,147,483,648 to +2,147,483,647
Counter Resolution
 FX
0(S)
FX
0N
FX
FX
(2C)
FX
2N(C)
General 16bit up
counter
14
(C0 - 13)
16
(C0 - 15)
100
(C0 - 99)
Latched 16bit up
counter
2
(C14 - 15)
16
(C16 - 31)
100
(C100 - 199)
General 32bit
bi-directional counter
N/A
N/A
20
(C200 - 219)
Latched 32bit
bi-directional counter
N/A
N/A
15
(C220 - 234)
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)
X1
K345
X2
C12
RST
C12