STEP 13-LEAK TESTING (TO BE PERFORMED IN A WELL-VENTILATED AREA.)
 
Supplies Needed for a Leak Test
 Clean paint brush, water, and dishwashing liquid
 
How to perform a leak test 
 WARNING! Never use an open flame to test for 
gas  leaks.
 1) Mix one cup of water with one cup of  dish washing 
      liquid. 
 2) Confirm that all control knobs on the control panel 
are       in the off position.
 3) Remove control knobs and the three retaining screws at 
     the bottom of the control panel.
 4) Remove front control panel cover.
5)  Open valve on LP gas cylinder (Turn counter- 
      clockwise).
6)  Check for leaks by brushing the soap solution on all 
LP       gas connections and fittings.  Make sure you  
      generously brush the seven locations with the 
soap       solution, completely surrounding  the connections 
and       fittings (See diagram below.)         
           
7)  If “growing” bubbles appear on any of the connection 
     points, then you have detected a gas leak. Immediately 
     close  the LP cylinder valve.  
     A) If leak appears at either end of hose and regulator 
         assembly, retighten the connection at the leak, 
but           do not overtighten.  (Note: Only hand tighten 
at           coupling nut)  (See Step 12 of Assembly           Ins
tructions)  Repeat Leak Test. 
     B) If  the leak is coming  from the LP gas cylinder, 
from           the valves at the control knobs, or if the leak 
cannot           be stopped, do not use the grill. Call Custome
r           Service at 1-800-251-7558.
8)  Always turn off LP cylinder valve after performing a leak 
     test. (Turn clockwise to a full stop.)
9)  If your LP gas grill has been in storage or has not been 
     used  for a period of time, the burners should be 
     maintained.  See Burner Maintenance in the Care and 
     Maintenance section of  this manual.
·  
Perform a leak test before each use.
·  Leak test must be performed in a well 
ventilated    area. 
·  Never perform a leak test on a grill while in use
   or hot.
·  If you detect a gas leak that cannot be corrected 
by    using the leak test procedures below, do not 
use    the LP gas grill. 
·  Never smoke or have an open flame near the 
grill    during a leak test.
·  Insure Regulator Hose does not contact hot 
metal    surfaces.