4. OPERATION AND FUNCTIONS 
4 -  5 
 
(2)  For the absolute position detection system 
 
POINT  
Be sure to turn on the Z-phase pulse in JOG operation after the magnetic pole 
detection. 
 
 
Carry out the magnetic pole detection referring the following procedure. 
 
(a)  Set the parameter No.PS01 (Special function selection 1) to "
1 (Magnetic pole detection always 
valid)". 
1
Magnetic pole detection always valid (initial value)
Parameter No.PS01
 
(b)  Execute the magnetic pole detection. (Refer to (1) (a) and (b) in this section) 
 
(c)  Change the parameter No.PS01 to "
0 (Magnetic pole detection not valid)" after the normal 
completion of magnetic pole detection. 
0
Magnetic pole detection invalid
Parameter No.PS01
 
By turning on the Z-phase pulse in JOG operation and by making the magnetic pole detection function 
invalid with the parameter No.PS01 after the magnetic pole detection, the magnetic pole detection for 
each power-on will be unnecessary.