5. PARAMETERS 
5 -  10 
 
Classification  No. 
Symbol 
Name and function 
Initial 
value 
Unit Setting 
range 
PS06 
LB2 
Servo control speed deviation error detection level 
Used to set the speed deviation error detection level of the servo control 
error detection. When the difference between the model feedback 
speed and the feedback speed is bigger than this setting value, the 
servo control error is detected (42). (Refer to section 4.4) 
100 
r/min 
1 to 2000 
PS07 
LB3 
Servo control to torque deviation error detection level 
Used to set the torque deviation error detection level of the servo control 
error detection. When the difference between the command torque and 
the feedback torque is bigger than this setting value, the servo control 
error is detected (42). (Refer to section 4.4) 
100 
 
1 to 1000 
PS08 
*LIT3  Special function selection 3 
Select the valid/invalid setting of the stroke limit and the magnetic pole 
detection method for the magnetic pole detection. (Refer to section 
4.2.3) 
When the stroke limit (FLS and RLS) of the servo amplifier is not used, 
invalidate the stroke limit for the magnetic pole detection. 
Method selection for the magnetic pole detection
0: Position detection method
4: Minute position detection method
1
0
Valid/invalid setting of the stroke limit (FLS and 
RLS) for the magnetic pole detection
0: Valid
1: Invalid
0010h 
 
Refer to the 
name and 
function 
column 
PS09 LPWM Magnetic pole detection voltage level 
Used to set the direct current exciting voltage level during the magnetic 
pole detection. When the overload alarm (50 and 51) or overcurrent 
alarm (32) occurs, set the smaller value. When the initial magnetic pole 
detection error occurs during the magnetic pole detection, set the bigger 
value. (Refer to section 4.2.4) 
30 
 
0 to 100 
PS10 
0005h 
PS11 
For manufacturer setting 
Do not change these values by any means. 
0064h 
PS12  
01F4h 
PS13  
0000h 
PS14  
0000h 
PS15  
0000h 
S
pec
ia
l s
et
ting param
et
ers
 
PS16 
 
 0000h