Справочник Пользователя для Mitsubishi Electronics FR-D720-008

Скачать
Страница из 294
96
Setting of acceleration/deceleration time and acceleration/ deceleration pattern
4.7 Setting of acceleration/deceleration time and acceleration/
deceleration pattern
4.7.1
Setting of the acceleration and deceleration time
 (Pr. 7, Pr. 8, Pr. 20, Pr. 44, Pr. 45)
Purpose
Parameter that should be Set
Refer to Page
Motor acceleration/deceleration 
time setting
Acceleration/deceleration 
times
Pr. 7, Pr. 8, Pr. 20, Pr. 44, Pr. 45
Starting frequency
Starting frequency and 
start-time hold
Pr. 13, Pr. 571
Set acceleration/deceleration 
pattern suitable for application
Acceleration/deceleration 
pattern
Pr. 29
Used to set motor acceleration/deceleration time.
Set a larger value for a slower speed increase/decrease or a smaller value for a faster speed increase/decrease.
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr. 611 Acceleration time at a
restart (page 136).
Parameter 
Number
Name
Initial Value
Setting 
Range
Description
7
Acceleration time
FR-D720-165 or less
FR-D740-080 or less
FR-D720S-008 to 100
5s
0 to 3600s
Motor acceleration time.
FR-D720-238 or more
FR-D740-120 or more
10s
8
Deceleration time
FR-D720-165 or less
FR-D740-080 or less
FR-D720S-008 to 100
5s
0 to 3600s
Motor deceleration time.
FR-D720-238 or more
FR-D740-120 or more
10s
20
Acceleration/
deceleration 
reference frequency
60Hz
1 to 400Hz
Frequency that will be the basis of 
acceleration/deceleration time.
As acceleration/deceleration time, set the 
frequency change time from stop to Pr. 20.
44
Second acceleration/
deceleration time
FR-D720-165 or less
FR-D740-080 or less
FR-D720S-008 to 100
5s
0 to 3600s
Acceleration/deceleration time when the RT 
signal is on.
FR-D720-238 or more
FR-D740-120 or more
10s
45
Second deceleration 
time
9999
0 to 3600s
Deceleration time when the RT signal is on.
9999
Acceleration time = deceleration time
∗1
The above parameters can be set when Pr. 160 Extended function display selection = "0". (Refer to page 162)
(1) Acceleration time setting (Pr. 7, Pr. 20)
Use  Pr. 7  Acceleration time to set the acceleration time required to reach Pr. 20
Acceleration/deceleration reference frequency from 0Hz.
Set the acceleration time according to the following formula.
Acceleration 
time setting
=
Pr. 20
×
Acceleration time from stop to maximum 
operating frequency
Maximum operating 
frequency - Pr. 13
Example)When Pr. 20 = 60Hz (initial value), Pr. 13 = 0.5Hz, and acceleration can be
made up to the maximum operating frequency of 50Hz in 10s
Pr. 7 =
60Hz
× 10s
12.1s
50Hz - 0.5Hz
Running
frequency
Acceleration time
Pr. 7, Pr. 44
Deceleration time
Pr. 8, Pr. 45
Time
Pr. 20
(60Hz)
(Hz)
Output
frequency