149
(current) of the motor
4
(1) Selection method of Advanced magnetic flux vector control
REMARKS
· When higher accuracy operation is necessary, set online auto tuning after performing offline auto tuning and select Real
sensorless vector control.
Perform secure wiring.
(Refer to page 14)
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to page 92)
Test run
Set the motor. (Pr. 71)
Set the operation command. (Refer to page 313)
As required
· Perform offline auto tuning.  (Pr. 96) (refer to page 189)
· Select online auto tuning.  (Pr. 95) (refer to page 199)
Select the start command and speed command.
(1) Start command
1. Operation panel :
Setting by pressing 
 /
  of the operation panel
2. External command : Setting by forward rotation or reverse
rotation command (terminal STF or STR)
(2) Speed command
1. Operation panel :
Setting by 
 of the operation panel
2. External analog command (terminal 2 or 4) :
Give a speed command using the analog signal input to
terminal 2 (or terminal 4).
3. Multi-speed command :
The external signals (RH, RM, RL) may also be used to give
speed command.
Set motor capacity (kW) in Pr. 80 Motor capacity  and the number 
of motor poles (number of poles) in Pr. 81 Number of motor poles.
(V/F control is performed when the setting is "9999" (initial value).)
Motor
Pr. 71 Setting 
REMARKS
Mitsubishi standard 
motor
Mitsubishi high 
efficiency motor
SF-JR
0 (initial value)
SF-JR 4P 1.5kW or lower
20
SF-HR
40
Others
3
Offline auto tuning is necessary. 
Mitsubishi constant-
torque motor
SF-JRCA 4P
1
SF-HRCA
50
Others (SF-JRC, etc.)
13
Offline auto tuning is necessary
Other 
manufacturer's 
standard motor
3
Offline auto tuning is necessary. 
Other 
manufacturer's 
constant torque 
motor
13
Offline auto tuning is necessary. 
*1
For other settings of Pr. 71 , refer to page 187.
*2
Refer to page 189 for offline auto tuning.