Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
172
Setting of acceleration/deceleration time 
and acceleration/deceleration pattern
4.12 Setting of acceleration/deceleration time and 
acceleration/deceleration pattern
4.12.1 Setting of the acceleration and deceleration time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, 
Pr. 44, Pr. 45, Pr. 110, Pr. 111, Pr. 147)
...............Specifications differ according to the date assembled. Refer to page 484  to check the SERIAL number.
Purpose
Parameter that must be Set
Refer to Page
Motor acceleration/deceleration time 
setting
Acceleration/deceleration time
Pr. 7, Pr. 8, Pr. 20, Pr. 21, 
Pr. 44, Pr. 45, Pr. 110, Pr. 111
Starting frequency
Starting frequency and start-
time hold
Pr. 13, Pr. 571
Set acceleration/deceleration pattern 
suitable for application
Acceleration/deceleration 
pattern and backlash measures
Pr. 29, Pr. 140 to Pr. 143, 
Pr. 380 to Pr. 383,
Pr. 516 to Pr. 519
Automatically set appropriate 
acceleration/deceleration time
Automatic acceleration/
deceleration
Pr. 61 to Pr. 63, Pr. 292
Use the following parameters to set motor acceleration/deceleration time.
Set a larger value for a slower speed increase/decrease or a smaller value for a faster speed increase/decrease.
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr. 611  Acceleration time at
a restart
 (page 266).
Parameter 
Number
Name
Initial Value
Setting Range
Description
7
Acceleration time
7.5K or lower
5s
0 to 3600/360s 
*1
Set the motor acceleration time.
11K or higher
15s
8
Deceleration time
7.5K or lower
5s
0 to 3600/360s
 *1
Set the motor deceleration time.
11K or higher
15s
20
Acceleration/
deceleration 
reference frequency
60Hz
1 to 400Hz
Set the frequency that will be the basis of 
acceleration/deceleration time. 
As acceleration/deceleration time, set the 
frequency change time from stop to Pr. 20.
21
Acceleration/
deceleration time 
increments
0
0
Increments: 0.1s
Range: 0 to 3600s
Increments and setting 
range of acceleration/
deceleration time 
setting can be 
changed.
1
Increments: 0.01s
Range: 0 to 360s
44
Second 
acceleration/
deceleration time
5s
0 to 3600/360s
 *1
Set the acceleration/deceleration time when 
the RT signal is ON.
45
Second 
deceleration time
9999
0 to 3600/360s
 *1
Set the deceleration time when the RT 
signal is ON.
9999
Acceleration time = deceleration time
110
Third acceleration/
deceleration time
9999
0 to 3600/360s
 *1
Set the acceleration/deceleration time when 
the X9 signal is ON.
9999
Without the third acceleration/deceleration 
function. 
111
Third deceleration 
time
9999
0 to 3600/360s
 *1
Set the deceleration time when the X9 
signal is ON.
9999
Acceleration time = deceleration time
147
Acceleration/
deceleration time 
switching 
frequency
9999
0 to 400Hz
The frequency where the acceleration/
deceleration time switches to the time set in 
Pr. 44 and Pr. 45.
9999
No function
*1
Depends on the Pr. 21 Acceleration/deceleration time increments setting. The initial value for the setting range is "0 to 3600s" and the setting
increments is "0.1s".