Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
176
Setting of acceleration/deceleration time 
and acceleration/deceleration pattern
4.12.3 Acceleration/deceleration pattern (Pr. 29, Pr. 140 to Pr. 143, Pr. 380 to Pr. 383,
Pr. 516 to Pr. 519)
You can set the acceleration/deceleration pattern suitable for application.
You can also set the backlash measures that stop acceleration/deceleration once at the parameter-set frequency
and time during acceleration/deceleration.
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
29
Acceleration/deceleration pattern 
selection
0
0
Linear acceleration/ deceleration
1
S-pattern acceleration/deceleration A
2
S-pattern acceleration/deceleration B
3
Backlash measures
4
S-pattern acceleration/deceleration C
5
S-pattern acceleration/deceleration D
140
Backlash acceleration stopping frequency
1Hz
0 to 400Hz
Set the stopping frequency and time for 
backlash measures.
Valid when Pr. 29 = 3
141
Backlash acceleration stopping time
0.5s
0 to 360s
142
Backlash deceleration stopping frequency
1Hz
0 to 400Hz
143
Backlash deceleration stopping time
0.5s
0 to 360s
380
Acceleration S-pattern 1
0
0 to 50%
Valid when S-pattern acceleration/
deceleration C (Pr. 29 = 4) is set.
Set the time taken for S-pattern from 
starting of acceleration/deceleration to 
linear acceleration as % to the 
acceleration/deceleration time (Pr. 7, Pr. 8 
etc.).
An acceleration/deceleration pattern can 
be changed with the X20 signal.
381
Deceleration S-pattern 1
0
0 to 50%
382
Acceleration S-pattern 2
0
0 to 50%
383
Deceleration S-pattern 2
0
0 to 50%
516
S-pattern time at a start of acceleration
0.1s
0.1 to 2.5s
Valid when S-pattern acceleration/
deceleration D (Pr. 29 = 5) is set.
Set the time taken for S-pattern 
acceleration/deceleration (S-pattern 
operation).
517
S-pattern time at a completion of 
acceleration
0.1s
0.1 to 2.5s
518
S-pattern time at a start of deceleration
0.1s
0.1 to 2.5s
519
S-pattern time at a completion of 
deceleration
0.1s
0.1 to 2.5s
(1) Linear acceleration/ deceleration (Pr. 29 = "0", initial value)
⋅ When the frequency is changed for acceleration, deceleration, etc. in inverter
operation, the output frequency is changed linearly (linear acceleration/
deceleration) to reach the set frequency without straining the motor and inverter.
Linear acceleration/deceleration has a uniform frequency/time slope.
(2) S-pattern acceleration/deceleration A (Pr. 29 = "1")
⋅ For machine tool spindle applications, etc.
Used when acceleration/deceleration must be made in a short time to a high-
speed range of not lower than the base frequency. In this acceleration/
deceleration pattern, Pr. 3 Base frequency (fb) is the inflection point of the S
pattern and you can set the acceleration/deceleration time appropriate for motor
torque reduction in a constant-power operation region of Pr. 3 Base frequency
(initial value = 60Hz) or higher.
CAUTION
⋅ As the acceleration/deceleration time of S-pattern acceleration/deceleration A, set the time taken until Pr. 3 Base frequency is
reached, not Pr. 20 Acceleration/deceleration reference frequency.
Setting value "0"
[Linear acceleration
/ deceleration]
Output frequency 
(Hz)
Time
fb
Output frequency 
(Hz)
Setting value "1"
Time
[S-pattern acceleration
/deceleration A]