4.21.5 Bias and gain of frequency setting voltage (current) 
(Pr. 125, Pr. 126, Pr. 241, C2(Pr. 902) to C7(Pr. 905), C12(Pr. 917) to C15(Pr. 918))
Frequency setting bias/gain parameter
Speed limit bias/gain parameter
You can set the magnitude (slope) of the output frequency as desired in relation to the frequency setting signal (0
to 5V, 0 to 10V or 0 to 20mADC).
Set Pr. 73, Pr. 267 and voltage/current input switch to switch between 0 to 5VDC, 0 to 10VDC and 4 to 20mADC.
(Refer to page 286)
Parameter 
Number
Name
Initial Value
Setting 
Range
Description
125
Terminal 2 frequency setting gain 
frequency
60Hz
 0 to 400Hz
Set the frequency of terminal 2 input gain 
(maximum).
126
Terminal 4 frequency setting gain 
frequency
60Hz
 0 to 400Hz
Set the frequency of terminal 4 input gain 
(maximum).
241
 
Analog input display unit 
switchover
0
0
Displayed in %
Select the unit of 
analog input display.
1
Displayed in V/mA
C2(902)
Terminal 2 frequency setting bias 
frequency
0Hz
 0 to 400Hz
Set the frequency on the bias side of 
terminal 2 input.
C3(902)
 
Terminal 2 frequency setting bias 
0%
 0 to 300%
Set the converted % of the bias side 
voltage (current) of terminal 2 input.
C4(903)
Terminal 2 frequency setting gain
100%
 0 to 300%
Set the converted % of the gain side 
voltage (current)  of terminal 2 input.
C5(904)
Terminal 4 frequency setting bias 
frequency
0Hz
 0 to 400Hz
Set the frequency on the bias side of 
terminal 4 input.
C6(904) 
Terminal 4 frequency setting bias 
20%
 0 to 300%
Set the converted % of the bias side 
current (voltage) of terminal 4 input.
C7(905) 
Terminal 4 frequency setting gain
100%
 0 to 300%
Set the converted % of the gain side 
current (voltage) of terminal 4 input.
Parameter 
Number
Name
Initial Value
Setting 
Range
Description
C12(917)
Terminal 1 bias frequency (speed)
0Hz
 0 to 400Hz
Set the frequency (speed) on the bias side 
of terminal 1 input.
C13(917)
Terminal 1 bias (speed)
0%
 0 to 300%
Set the converted % of the bias side 
voltage of terminal 1 input.
C14(918) 
Terminal 1 gain frequency (speed)
60Hz
 0 to 400Hz
Set the frequency (speed) of terminal 1 
input gain (maximum).
C15(918) 
Terminal 1 gain (speed)
100%
 0 to 300%
Set the converted % of the gain side 
voltage of terminal 1 input.
*1
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
*2
The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write selection.