Frequency/torque setting by analog 
4.21.6 Bias and gain of torque (magnetic flux) setting voltage (current)
(Pr. 241, C16(Pr. 919) to C19(Pr. 920), C38 (Pr. 932) to C41 (Pr. 933)) 
 
(1) Change functions of analog input terminal
In the initial setting status, terminal 1 and terminal 4 used for analog input are respectively set to speed setting
auxiliary (speed limit auxiliary) and speed command (speed limit). To use an analog input terminal as torque
command, torque limit input or magnetic flux command input, set Pr. 868 Terminal 1 function assignment and Pr. 858
Terminal 4 function assignment
  to change functions. (Refer to page 285)
Magnetic flux command is valid only under vector control.
(2) The relationship between analog input terminal and calibration parameter
Terminal 1 functional calibration parameter
—: No function
* Use Pr. 148 Stall prevention level at 0V input and Pr. 149 Stall prevention level at 10V input to adjust bias/gain of stall prevention operation level.
You can set the magnitude (slope) of the torque as desired in relation to the torque setting signal (0 to 5VDC, 0 to
10V or 4 to 20mA).
Use Pr. 73 and Pr. 267  to switch from among 0 to 5V, 0 to 10V, 4 to 20mADC. (Refer to page 286)
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
Analog input display unit 
switchover
0
0
Displayed in %
Select the unit of analog input 
display.
1
Displayed in V/mA
C16(919) 
Terminal 1 bias command (torque/
magnetic flux)
0%
0 to 400%
Set the torque (magnetic flux) on the bias side of 
terminal 1 input.
C17(919) 
Terminal 1 bias (torque/magnetic 
flux)
0%
0 to 300%
Set the converted % of the bias side voltage 
(current) of terminal1 input.
C18(920) 
Terminal 1 gain command (torque/
magnetic flux)
150%
0 to 400%
Set the torque (magnetic flux) of the terminal 1 input 
gain (maximum).
C19(920) 
Terminal 1 gain (torque/magnetic 
flux)
100%
0 to 300%
Set the converted % of the gain side voltage of 
terminal1 input.
C38(932) 
Terminal 4 bias command (torque/
magnetic flux)
0%
0 to 400%
Set the torque (magnetic flux) on the bias side of 
terminal 4 input.
C39(932) 
Terminal 4 bias (torque/magnetic 
flux)
20%
0 to 300%
Set the converted % of the bias side current 
(voltage) of terminal 4 input.
C40(933) 
Terminal 4 gain command (torque/
magnetic flux)
150%
0 to 400%
Set the torque (magnetic flux) of the terminal 4 input 
gain (maximum).
C41(933) 
Terminal 4 gain (torque/magnetic 
flux)
100%
0 to 300%
Set the converted % of the gain side current 
(voltage) of terminal 4 input.
*1
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
*2
The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter
write selection 
.
Pr. 868 
Setting
Terminal 
Function
Calibration Parameters
Bias setting
Gain setting
0
(initial 
value)
Frequency (speed) 
setting auxiliary
C2(Pr. 902) Terminal 2 frequency setting bias frequency
C3(Pr. 902) Terminal 2 frequency setting bias 
C5(Pr. 904) Terminal 4 frequency setting bias frequency
C6(Pr. 904) Terminal 4 frequency setting bias 
Pr. 125 Terminal 2 frequency setting gain frequency
C4(Pr. 903) Terminal 2 frequency setting gain
Pr. 126 Terminal 4 frequency setting gain frequency
C7(Pr. 905) Terminal 4 frequency setting gain
1
Magnetic flux 
command
C16(Pr. 919) Terminal 1bias command (torque/magnetic flux)
C17(Pr. 919) Terminal 1bias (torque/magnetic flux)
C18(Pr. 920) Terminal 1 gain command (torque/magnetic flux)
C19(Pr. 920) Terminal 1 gain (torque/magnetic flux)
2
Regenerative 
torque limit
C16(Pr. 919) Terminal 1 bias command (torque/magnetic flux)
C17(Pr. 919) Terminal 1 bias (torque/magnetic flux)
C18(Pr. 920) Terminal 1 gain command (torque/magnetic flux)
C19(Pr. 920) Terminal 1 gain (torque/magnetic flux)
3
Torque command
4
Stall prevention 
operation level */
torque limit/torque 
command
5
Forward/reverse 
rotation speed limit
C12(Pr. 917) Terminal 1 bias frequency (speed)
C13(Pr. 917) Terminal 1 bias (speed)
C14(Pr. 918) Terminal 1 gain frequency (speed)
C15(Pr. 918) Terminal 1 gain (speed)
6
Torque bias input
C16(Pr. 919) Terminal 1 bias command (torque/magnetic flux)
C17(Pr. 919) Terminal 1 bias (torque/magnetic flux)
C18(Pr. 920) Terminal 1 gain command (torque/magnetic flux)
C19(Pr. 920) Terminal 1 gain (torque/magnetic flux)
9999
Sensorless
Sensorless
Sensorless
Vector
Vector