Setting of the parameter unit and
operation panel
4
(2) Disable the setting dial and key operation of the operation panel (Press [MODE] long (2s))
⋅ Operation using the setting dial and key of the operation panel can be invalid to prevent parameter change,  and
unexpected start or frequency setting.
⋅ Set "10 or 11" in Pr. 161, then press 
 for 2s to make the setting dial and key operation invalid.
⋅ When the setting dial and key operation are invalid, 
 appears on the operation panel. If dial or key
operation is attempted while dial and key operation are invalid, 
 appears (When dial or key is not
touched for 2s, monitor display appears. )
⋅ To make the setting dial and key operation valid again, press 
 for 2s.
4.27.3 Buzzer control (Pr. 990)
The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write 
selection
.
4.27.4 PU contrast adjustment (Pr. 991)
The above parameters are displayed as simple mode parameters only when the parameter unit (FR-PU04/FR-PU07) is connected.
REMARKS
⋅ Even if the setting dial and key operation are disabled, the monitor display 
 is valid.
CAUTION
• Release the operation lock to release the PU stop by key operation.
You can make the buzzer "beep" when you press key of the operation panel (FR-DU07) and parameter unit (FR-
PU04/FR-PU07). 
Parameter 
Number
Name
Initial Value
Setting Range
Description
990
PU buzzer control
1
0
Without buzzer sound
1
With buzzer sound
REMARKS
Inverter alert faults with buzzer sounds when this parameter is set to activate the buzzer sound.
Contrast adjustment of the LCD of the parameter unit (FR-PU04/FR-PU07) can be performed.
Decreasing the setting value makes the contrast lighter.
Parameter 
Number
Name
Initial Value
Setting Range
Description
991
PU contrast adjustment
58
0 to 63
0 : Light

63: Dark