457
Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type with brake)
Dimensions table
(Unit: mm)
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is 
4 The 400V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side.)
Frame Number 90L
SF-V5RUF(H) 
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H) , , , 
Frame Number 160M, 160L
SF-V5RUF(H) , 
SF-V5RU
F…KB
SF-V5RU
F…K1B
SF-V5RU
F…K3B
SF-V5RU
F…K4B
Flange 
Number
Frame 
No.
Mass
(kg)
Motor
Shaft End
Terminal Screw Size
D
KB
KD
KL
KP
LA
LB
LC
LE
LG
LL
LN
LZ
LR
Q
QK
S
T
U
W
U,V,W A,B,(C) B1,B2 G1,G2
1
FF165
90L
31.5
183.6 198.5
27
220
155
165
130j6
200
3.5
12
442
4
12
50
50
40
24j6
7
4
8
M6
M4
M4
M4
2
1
FF215 100L
50
207
213
27
231
165
215
180j6
250
4
16
481.5
4
14.5
60
60
45
28j6
7
4
8
M6
M4
M4
M4
3
2
1
FF215 112M
58
228
239
27
242
178
215
180j6
250
4
16
525
4
14.5
60
60
45
28j6
7
4
8
M6
M4
M4
M4
5
3
2
FF265 132S
83
266
256
27
256
197
265
230j6
300
4
20
597
4
14.5
80
80
63
38k6
8
5
10
M6
M4
M4
M4
7
5
3
1
FF265 132M
88
266
294
27
256
197
265
230j6
300
4
20
635
4
14.5
80
80
63
38k6
8
5
10
M6
M4
M4
M4
11
7
5
2
FF300 160M
151
318
318
56
330
231
300
250j6
350
5
20
735.5
4
18.5
110
110
90
42k6
8
5
12
M8
M4
M4
M4
15
11
7
3
FF300 160L
167
318
362
56
330
231
300
250j6
350
5
20
779.5
4
18.5
110
110
90
42k6
8
5
12
M8
M4
M4
M4
1KB
2KB
3KB
5KB
7KB
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Suction
Exhaust
Direction of 
cooling fan wind
Terminal box for cooling fan
1
2
B
B
Section
AA
LC
LB
LG
LE
LL
LR
Q
QK
D
KB
LN   LZ
1
2
KD
A
A
LA
KL
φ
22
KP
Section BB
U
W
T
S
Main 
terminal box
Section BB
W
S
U
T
Connector (for encoder)
MS3102A20-29P
QK
Q
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Suction
Exhaust
Direction of 
cooling fan wind
Terminal box for cooling fan
1
2
Section
AA
LC
LB
B
B
LR
LG
LE
LL
D
KB
A
LN    LZ
A
1
2
LA
KD
KL
φ
22
KP
Main 
terminal box
V
U
B2
B1
W G1 G2
C
B
A
For motor (U, V, W)
For cooling fan (A, B)
For brake (B1, B2)
For thermal protector (G1, G2)
Earthing 
(grounding) 
terminal (M4)
Earthing 
(grounding) 
terminal (M4)
Main terminal box
Terminal box for cooling fan
11KB 15KB
Section BB
W
S
U
T
A
A
LN    LZ
2
1
LA
KD
KL
φ
22
KP
Connector (for encoder)
MS3102A20-29P
QK
Q
D
Earth (ground) terminal (M8)
Mark for earthing (grounding)
Suction
Direction of 
cooling fan wind
Terminal box for cooling fan
1, 2
Section
AA
LC
LB
B
B
LL
KB
LR
LG
LE
Exhaust
Main 
terminal box
B2
B1
U
G2
G1
W
V
C
B
A
For cooling fan (A, B, C)
For motor (U, V, W)
Earthing 
(grounding) 
terminal (M8)
Earthing 
(grounding) 
terminal (M4)
For brake (B1, B2)
For thermal protector (G1, G2)
Terminal box for cooling fan
Main terminal box
 indicates an inserting position of a bolt with hex head holes 
for manual opening.
Make sure to earth the earth terminal of the flange section 
as well as the earth terminal in the terminal box.
-0.5