Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
6/24
BCN-C22005-634
(2) IPM parameter initialization list
The parameter settings in the following table are changed to the settings required to perform PM sensorless
vector control by selecting PM sensorless vector control with the IPM parameter initialization mode on the
operation panel or with Pr. 998 IPM parameter initialization setting. The changed settings differ according to the
IPM motor specification (capacity).
Performing parameter clear or all parameter clear sets back the parameter settings to the settings required to
drive a general-purpose motor.
*1
Initial values differ according to the inverter capacity. (55K or lower/75K or higher)
*2
Setting Pr. 71 Applied motor = one of "333, 334, 8093, 8094" does not change the Pr. 71 Applied motor setting.
*3
Setting Pr. 80 Motor capacity 
 "9999" does not change the Pr. 80 Motor capacity setting.
*4
This parameter can be set when FR-A7NL is mounted.
*5
200r/min when Pr. 788 Low-speed range torque characteristics = "0".
*6
13.33Hz when Pr. 788 Low-speed range torque characteristics = "0".
Parameter
Name
Setting
Setting 
increments
General-
purpose motor
IPM motor 
(rotations per minute)
IPM motor 
(frequency)
Pr.998
(Initial setting)
3003
(MM-CF)
8009 (other 
than MM-CF)
3103
(MM-CF)
8109 (other 
than MM-CF)
3003, 
8009
0, 3103, 
8109
Maximum frequency
120/60Hz *1
3000r/min
200Hz
1r/min 0.01Hz
Multi-speed setting (high speed)
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
Electronic thermal O/L relay
Rated inverter 
current
Rated motor 
current
(Refer to page 16)
Rated motor 
current
(Refer to page 16)
0.01A/0.1A *1
13
Starting frequency
0.5Hz
Pr. 84 
10%
Pr. 84 
10% 1r/min 0.01Hz
15
Jog frequency
5Hz
200r/min
Pr. 84 
10%
13.33Hz
Pr. 84 
10% 1r/min 0.01Hz
18
High speed maximum frequency 120/60Hz *1
3000r/min
200Hz
1r/min 0.01Hz
20
Acceleration/deceleration 
reference frequency
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
22
Stall prevention operation level
150%
150%
0.1%
37
Speed display
0
0
1
55
Frequency monitoring reference
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
56
Current monitoring reference
Rated inverter 
current
Rated motor 
current
(Refer to page 16)
Pr. 859
Rated motor 
current
(Refer to page 16)
Pr. 859
0.01A/0.1A *1
71
Applied motor
0
330 *2
330 *2
1
80
Motor capacity
9999
Motor capacity
(MM-CF) *3
Motor capacity
(MM-CF) *3
0.01kW/0.1kW 
81
Number of motor poles
9999
8
8
1
84
Rated motor frequency
60Hz
2000r/min
133.33Hz
1r/min 0.01Hz
125 (903)
Terminal 2 frequency setting 
gain frequency
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
126 (905)
Terminal 4 frequency setting 
gain frequency
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
144
Speed setting switchover
4
108
Pr. 81 +100
8
Pr. 81
1
240
Soft-PWM operation selection
1
0
1
263
Subtraction starting frequency
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
266
Power failure deceleration 
time switchover frequency
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
374
Overspeed detection level
140Hz
3150r/min
Pr. 1 (Pr. 18)  

105%
210Hz
Pr. 1 (Pr. 18)  

105%
1r/min 0.01Hz
386
Frequency for maximum input pulse
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
390
 *4 % setting reference frequency
60Hz
133.33Hz
Pr. 84
133.33Hz
Pr. 84
0.01Hz
505
Speed setting reference
60Hz
133.33Hz
Pr. 84
133.33Hz
Pr. 84
0.01Hz
557
Current average value 
monitor signal output 
reference current
Rated inverter 
current
Rated motor 
current
(Refer to page 16)
Pr. 859
Rated motor 
current
(Refer to page 16)
Pr. 859
0.01A/0.1A *1
820
Speed control P gain 1
60%
30%
1%
821
Speed control integral time 1
0.333s
0.333s
0.001s
824
Torque control P gain 1
100%
100%
1%
825
Torque control integral time 1
5ms
20ms
0.1ms
870
Speed detection hysteresis
0Hz
8r/min
0.5Hz
1r/min 0.01Hz
885
Regeneration avoidance 
compensation frequency limit value
6Hz
200r/min
Pr. 84 
10%
13.33Hz
Pr. 84 
10% 1r/min 0.01Hz
893
Energy saving monitor 
reference (motor capacity)
Rated inverter 
capacity
Motor capacity (Pr. 80)
0.01kW/0.1kW 
C14 (918)
Terminal 1 gain frequency (speed)
60Hz
2000r/min
Pr. 84
133.33Hz
Pr. 84
1r/min 0.01Hz
: The setting does not change.
REMARKS
If IPM parameter initialization is performed in rotations per minute (Pr. 998 = "3003" or "8009"), the parameters not
listed in the table above are also set and displayed in rotations per minute. 
bcnc22005634.fm  6 ページ  2012年7月3日 火曜日 午前9時43分