Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
84
Param
e
te
r List
Parameter List
Cal
ibra
tion paramet
e
rs
C12
(917)
Terminal 1 bias frequency (speed)
0 to 400Hz
0.01Hz
0Hz
C13
(917)
Terminal 1 bias (speed)
0 to 300%
0.1%
0%
C14
(918)
Terminal 1 gain frequency (speed)
0 to 400Hz
0.01Hz
60
Hz
C15
(918)
Terminal 1 gain (speed)
0 to 300%
0.1%
100%
C16
(919)
Terminal 1 bias command (torque/
magnetic flux)
0 to 400%
0.1%
0%
C17
(919)
Terminal 1 bias (torque/magnetic flux)
0 to 300%
0.1%
0%
C18
(920)
Terminal 1 gain command (torque/
magnetic flux)
0 to 400%
0.1%
150%
C19
(920)
Terminal 1 gain (torque/magnetic flux)
0 to 300%
0.1%
100%
C38
(932)
Terminal 4 bias command (torque/
magnetic flux)
0 to 400%
0.1%
0%
C39
(932)
Terminal 4 bias (torque/magnetic flux)
0 to 300%
0.1%
20%
C40
(933)
Terminal 4 gain command (torque/
magnetic flux)
0 to 400%
0.1%
150%
C41
(933)
Terminal 4 gain (torque/magnetic flux)
0 to 300%
0.1%
100%
989
Parameter copy alarm release
10/100
1
10/100
PU
990
PU buzzer control
0, 1
1
1
991
PU contrast adjustment
0 to 63
1
58
Clear
pa
ra
me
te
rs
Pr. CL
Parameter clear
0, 1
1
0
ALLC
All parameter clear
0, 1
1
0
Er.CL
Faults history clear
0, 1
1
0
PCPY
Parameter copy
0, 1, 2, 3
1
0
*1
Differ according to capacities.
6%: 0.4K, 0.75K
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K to 55K
1%: 75K or higher
*2
Differ according to capacities.
 (55K or lower/75K or higher)
*3
Differ according to capacities. 
5s: 7.5K or lower
15s: 11K or higher
*4
Differ according to capacities. 
4%: 7.5K or lower
2%: 11K to 55K
1%: 75K or higher
*5
Differs according to the voltage class. (200V class/400V class)
*6
Setting can be made only when the FR-A7AP/FR-A7AL is mounted.
*7
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
Func-
tion
Parameter
Name
Setting Range
Minimum 
Setting
Increments
Initial Value
Refer 
to 
Page
Customer 
Setting