Справочник Пользователя для Furuno 711c
6. INSTALLATION AND WIRING
6-5
6.2
Wiring
A maximum of six control units can be connected. The TB8 port of the processor unit
has two connection lines for the control unit. Three control units can be connected in
a daisy chain connection per each connection line.
has two connection lines for the control unit. Three control units can be connected in
a daisy chain connection per each connection line.
The rear side of the control unit
Ground terminal
To processor unit,
other control unit, or
terminator
other control unit, or
terminator
Cable assy. (BD-07AFFM-LR-100/150) or
Terminator (BD-07AFFM-LR7001)
Ground wire
(IV-1.25 sq.)
(IV-1.25 sq.)
Ship's ground
To processor unit,
other control unit, or
terminator
other control unit, or
terminator
Signal connector:
Each I/O interface is same.