96
4.2.23 Automatic restart after instantaneous power failure 
 
(Pr. 57, Pr. 58, Pr. 162, Pr. 165, Pr. 611)
Pr. 57 "restart coasting time"
Pr. 58 "restart cushion time"
Pr. 162 "automatic restart after instantaneous power failure selection"
Pr. 163 "first cushion time for restart"
Pr. 164 "first cushion voltage for restart"
Pr. 165 "restart stall prevention operation level"
Pr. 611 "restart acceleration time"
z
 You can restart the inverter without stopping the motor (with the motor coasting) when the commercial
power supply is switched to the inverter operation or when the power is restored after an instantaneous
power failure. (When automatic restart operation is set to be enabled, restart after instantaneous power
failure is performed without outputting alarm output signals, E.UVT (under voltage protection) and E.IPF
(instantaneous power failure protection),  at occurrence of an instantaneous power failure.
Parameter 
Number
Factory 
Setting
Setting Range
Remarks
57
9999
0, 0.1 to 5 s, 9999
9999: No restart
58
1.0 s
0 to 60 s
162
0 s
0, 1
0: Frequency 
search
1: No frequency 
search
163
0 s
0 to 20 s
164
0%
0 to 100%
165
150%
0 to 200%
611
5.0s
0 to 3600s, 9999
STF
IM
NFB
CS
SD
CS
SD
MC1
MC2
×
MC3
W
V
U
Connect CS-SD for use of only
automatic restart after instantaneous 
power failure.
MC switching sequence
S1
R1
T
S
R
Instantaneous power failure time
ower supply (R, S, T)
Motor speed
N (r/min)
Inverter output
frequency
f (Hz)
Inverter output
voltage
E (V)
Coasting
time
speed 
detection time
+
Pr. 57 setting
When Pr. 162=0 (with frequency search)
Coasting time
Pr. 57 setting.
Cushion voltage time
Pr. 58 setting
When Pr. 162=1 (without frequency search)
Instantaneous power failure time
Motor speed
N (r/min)
Inverter output
frequency
f (Hz)
Inverter output
voltage
E (V)
Power supply (R, S, T)
Cushion voltage time (value set in Pr. 58)
Restart acceleration time. ( Pr. 611 setting)