4.2.27 Retry function (Pr. 65, Pr. 67 to Pr. 69)
Pr. 65 "retry selection"
Pr. 67 "number of retries at alarm occurrence"
Pr. 68 "retry waiting time"
Pr. 69 "retry count display erasure"
When an alarm occurs, the retry function causes the inverter to automatically reset itself to make a restart
and continue operation. You can select whether retry is made or not, alarms reset for retry, number of retries
made, and waiting time.
When you have selected automatic restart after instantaneous power failure, restart operation is performed
at the retry operation time which is the same of that of a power failure. (Refer to page 96 for restart function.) 
<Setting>
Use Pr. 65 to select alarms to be reset for retry.
Note: 
z
 indicates the errors selected for retry.
Parameter 
Number
Factory Setting
Setting Range
65
0
0 to 5
67
0
0 to 10, 101 to 110
68
1 s
0 to 10 s
69
0
0
Errors Reset for Retry
Setting
Display
0
1
2
3
4
5
E.OC1
z
z
z
z
z
E.OC2
z
z
z
z
E.OC3
z
z
z
z
z
E.OV1
z
z
z
z
E.OV2
z
z
z
z
E.OV3
z
z
z
z
E.THM
z
E.THT
z
E.IPF
z
z
E.UVT
z
z
E.FIN
E. BE
z
z
E. GF
z
z
E. LF
E.OHT
z
E.OLT
z
z
E.OPT
z
z
E.OP1
z
z
E.OP2
z
z
E.OP3
z
z
E. PE
z
z
E.PUE
E.RET
E.CPU
E.  1
E.  2
E.  3
E.  6
E.  7
E.MB1
z
z
E.MB2
z
z
E.MB3
z
z
E.MB4
z
z
E.MB5
z
z
E.MB6
z
z
E.MB7
z
z
E.P24
E.CTE
E.ECT
E.OSD
z
z