Справочник Пользователя для Mitsubishi Electronics FR-A500
230
8.1 Option List
8.1.1
Stand-alone options
Name
Type
Application, Specifications, etc.
Applicable
Inverter
Parameter unit
(8 languages)
(8 languages)
FR-PU04
Interactive parameter unit using LCD display (For use in
Japanese, English, German, French, Spanish, Italian, Swedish
and Finnish)
Japanese, English, German, French, Spanish, Italian, Swedish
and Finnish)
Common to
all models
all models
Parameter unit
connection cable
connection cable
FR-CB2
Cable for connection of the operation panel or parameter unit.
Heatsink outside
attachment
attachment
FR-A5CN
Used to place only the heat generating section of the inverter in
the back of the control box.
the back of the control box.
1.5K to 55K,
according to
capacity
according to
capacity
Totally enclosed
structure attachment
structure attachment
FR-A5CV
By installing this option, the inverter meets the totally enclosed
structure specifications (IP40).
structure specifications (IP40).
0.4K to 22K,
according to
capacity
according to
capacity
Attachment for conduit
connection
connection
FR-A5FN
Used to connect a conduit directly.
30K to 55K,
according to
capacity
according to
capacity
FR-A200E series
installation interchange
attachment
installation interchange
attachment
FR-A5AT
Mounting plate used to make the mounting dimensions identical to
those of the FR-A200<EXCELLENT> series.
those of the FR-A200<EXCELLENT> series.
0.4K to 55K,
according to
capacity
according to
capacity
EMC Directive
compatible noise filer
(Note 3)
compatible noise filer
(Note 3)
SF
Noise filer conforming to the EMC Directive (EN50081-2)
0.4 to 55K,
according to
capacity
according to
capacity
High-duty brake resistor
FR-ABR-(H)
(Note 1)
Used to improve the braking capability of the brake built in the
inverter.
inverter.
0.4K to 7.5K,
according to
capacity
according to
capacity
Surge voltage
suppressing filter
suppressing filter
FR-ASF-H
Suppresses surge voltages on the inverter output side.
0.4 to 55K,
according to
capacity
according to
capacity
Power factor improving
DC reactor
DC reactor
FR-BEL-(H)
(Note 1)
Used to improve the inverter input power factor (overall power
factor about 95%) and cooperate with the power supply.
factor about 95%) and cooperate with the power supply.
0.4K to 55K,
according to
capacity
according to
capacity
Power factor improving
AC reactor
AC reactor
FR-BAL-(H)
(Note 1)
Used to improve the inverter input power factor (overall power
factor about 90%) and cooperate with the power supply.
factor about 90%) and cooperate with the power supply.
0.4K to 55K,
according to
capacity
according to
capacity
Radio noise filter
FR-BIF-(H)
(Note 1)
For radio noise reduction. Leakage current 4mA.
Common to
all models
all models
Line noise filter
FR-BSF01
For line noise reduction (applies to small capacities of 3.7kW or
less)
less)
FR-BLF
For line noise reduction
BU brake unit
BU-1500 to 15K,
H7.5K to H30K
H7.5K to H30K
Used to improve the braking capability of the inverter (for high-
inertia load or negative load).
inertia load or negative load).
According to
capacity
capacity
Brake unit
FR-BU-15K to 55K,
H15K to H55K
H15K to H55K
Used to improve the braking capability of the inverter (for high-
inertia load or negative load). Use the brake unit and resistor unit
together.
inertia load or negative load). Use the brake unit and resistor unit
together.
Resistor unit
FR-BR-15K to 55K,
H15K to H55K
H15K to H55K
Power regeneration
converter
converter
FR-RC-15K to 55K,
H15K to H55K
H15K to H55K
High-function brake unit which can return motor-generated
braking energy to the power supply.
braking energy to the power supply.
Power regeneration
common converter
common converter
FR-CV 7.5K to 30K(-
AT), 37K, 55K, H7.5K
to H30K(-AT), H37K,
H55K (Note 5)
AT), 37K, 55K, H7.5K
to H30K(-AT), H37K,
H55K (Note 5)
High function unit that can regenerate the braking energy
generated by the motor to the power supply in common converter
system.
generated by the motor to the power supply in common converter
system.
FR-CV dedicated
stand-alone reactor
stand-alone reactor
FR-CVL-7.5K to 55K,
H7.5K to H55K
H7.5K to H55K
FR-CV dedicated power cooperative reactor.
High power factor
converter
converter
FR-HC7.5K to 55K,
H7.5K to H55K
H7.5K to H55K
The high power factor converter switches the converter circuit on-
off to convert the input current waveform into a sine wave to
suppress harmonics considerably. (Used with the standard
accessories.)
off to convert the input current waveform into a sine wave to
suppress harmonics considerably. (Used with the standard
accessories.)