3.2.5
Parameter setting method
A parameter value may either be set by updating its parameter number or setting the value digit-by-digit
using the 
 key.
To write the setting, change it and press the 
 key 1.5s.
Example: To change the Pr. 79 "operation mode selection" setting from "2" (external operation mode) to "1"
(PU operation mode)
(For details of Pr. 79, refer to page 113.)
SET
STOP
RESET
MODE
SET
SET
SET
SET
SET
SET
SET
When               appears
1) When the [FWD] or [REV] indication is lit, 
    stop operation by pressing the                 key 
    or turning off the forward rotation (STF) 
    or reverse rotation (STR) signal connected 
    to the control terminal.
2) You cannot set any value that is outside the 
    parameter setting range. Write a value within
    the setting range.
z
Current setting
z
Setting change
Press for
1.5 s 
Middle digit flickers
Most significant
digit flickers
Least significant
digit flickers
0 to 9
z
Setting write
Flicker
To 3.2.6 Operation mode
0 to 9
×
7 times
  or
×
3 times
×
9 times
  or
×
1 times
"1" (PU operation mode) has been set in Pr. 79.
If the value and                 do not flicker but 
              appears, you did not press the        key
 for 1.5s when writing the value.
Press the        key once, press the        key, and 
restart the setting from the beginning.