61
3
3.3.3
PU operation mode
 (Operation using the operation panel (FR-DU04))
(1)  Operation at 60Hz
While the motor is running, repeat the following steps 2 and 3 to vary the speed:
(2)  PU jog operation
Hold down the 
 or 
 key to perform operation, and release it to stop. 
1) Set Pr. 15 "jog frequency" and Pr. 16 "jog acceleration/deceleration".
2) Select the PU jog operation. (Press the 
 key to choose the operation mode and press the 
key to switch to PU jog operation.)
3) Hold down the 
 or 
 key to perform operation.
(If the motor remains stopped, check Pr. 13 "starting frequency". The motor will not start if its setting is
lower than the starting frequency.)
Step
Description
Image
1
Power-on 
 Operation mode check
Switch power on and make sure that the operation command
indication "PU" is lit.
(If it is not lit, press the 
 key to choose the operation mode and 
press the 
 key to switch to PU operation.)
2
Running frequency setting
Set the running frequency to 60Hz.
First, press the
key to select the frequency setting mode. Then,
press the 
 key to change the setting, and press the
key to write the frequency
3
Start
Press 
the  
or  
key.
The motor starts running. The monitoring mode is automatically 
selected and the output frequency is displayed.
4
Stop
Press the 
 key.
The motor is decelerated to a stop.
MODE
ON
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
MODE
SET
(or)
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FWD
REV
REV
FWD
(or)
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
STOP
RESET
FR-DU04
CONTROL PANEL
Hz
MON
EXT
PU
A
V
REV
FWD
FWD
REV
MODE
FWD
REV