MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Unit Load Calculation 
Page F-2
Unit Load Rules 
F
Unit Load Rules
F
A general rule to follow is that if you can distribute the DID modules and telephone 
modules equally across the carriers, you will prevent unnecessary drain on any 
one carrier.
Also, depending on the system’s mode, the rules vary. This section provides the 
rules for calculating unit loads for the different modes.
Unit Loads for the Hybrid/PBX Mode
F
The 391A1 and 391A2 power supplies have a maximum rating of 54 unit loads 
and generally can support six modules of any type in a system in Hybrid/PBX 
mode 
 
without exceeding the 54-unit maximum. If, however, both of the 
following conditions are true, the unit loads on a carrier might exceed the 54-unit 
maximum:
All six carrier slots are occupied by MLX or analog multiline telephone 
modules
The carrier has a total of more than 45 MLX-20L telephones or 34-button 
analog multiline telephones installed
The 391C1 and 391A3 power supplies have a maximum rating of 75 unit loads. If 
your system contains a 391A1 or 391A2 power supply module, and the unit loads 
for that carrier will exceed 54, a 391C1 power supply should be installed in the 
system.
Unit Loads for Key or Behind Switch Mode
F
In a Key or Behind Switch system with four or fewer modules, no calculation is 
needed. The power supply generally supports four modules of any type in Key or 
Behind Switch mode.
Calculating Unit Loads
F
Use the worksheet and instructions in the remainder of this appendix to calculate 
unit loads for each carrier. Make a copy of all pages of the worksheet for each 
carrier.