Листовка для HP Accessory Fan Kit 581031-B21

Модели
581031-B21
Скачать
Страница из 24
System Unit
Dimensions (H x W x D)
(with bezel)
SFF Drives: 3.38 x 17.54 x 27.25 in (8.59 x 44.55 x 69.22 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
60.00 lb (27.27 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
47.18 lb (21.45 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
Rated Input Current
For 1200 W Power Supply:
10 A (at 100 VAC),
4.9 A (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
BTU Rating
Maximum
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
Power Specifications
NOTE: To review typical system power ratings use the HP Power Advisor
which is available online located at url: 
Power Supply Output
(per power supply)
Rated Steady-State Power For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
Maximum Peak Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
QuickSpecs
HP ProLiant DL380 Generation 6 (G6) – Carrier
Grade Supplement
Technical Specifications
DA - 13523   Worldwide QuickSpecs — Version 2 — 12.11.2009
Page 21