Lighting and Start Up Procedures
WARNING:
DO NOT HOLD GAS VALVE (D) IN MORE THAN 30 SECONDS. IF FLAME IS NOT INDICATED WITHIN
THIS TIME, TURN GAS TO OFF, WAIT 2 MINUTES AND RETRY. CONTINUING TO HOLD GAS VALVE IN
WILL CAUSE GAS BUILD-UP IN THE BURNER AREA AND CAN RESULT IN AN EXPLOSION WHICH
CAN CAUSE PERSONAL INJURY OR DEATH.
2-Way and 3-Way Models
Lighting Instructions: Gas Operation
1. Make certain that 12 Volts DC is available to
the refrigerator and divider switch is in NOR-
MAL position.
2. Turn on gas supply at the tank.
3. Set thermostat control (C) to COLDEST setting.
4. Set ignitor switch (A) to "ON" position. The tog-
gle light (A) located on the switch will illuminate
if 12 volts DC is present.
5. Push and rotate the "ELEC-OFF-GAS" control
(D) counter-clockwise so that "GAS" is visible
on the knob. Push the control knob (D) in and
hold until the flame indicator (B) illuminates
(continuous glow). Continue to hold approxi-
mately 5 seconds, then release. The flame indi-
cator (B) will remain on. If not repeat this step.
NOTE: In normal use the flame should ignite
within 10 seconds. On initial refrigerator
start-up, it may take longer than 10 sec-
onds to allow air to be purged from the
gas line, as indicated by the flame indica-
tor (B) failing to illuminate.
Do not hold gas control valve (D) in more
than 30 seconds. See WARNING above.
6. Move thermostat control (C) to desired setting
7. The ignitor switch (A) should be left in the
"ON" position during  gas operation. If the
switch is turned off, the refrigerator will cycle
normally. However, in case of flame blowout,
the relighter does not function.
Start-Up Instructions: AC Electric Operation
1. Make certain that 120 Volts AC and 12 Volts
DC are available to the refrigerator and divider
switch is in NORMAL position.
2. Set thermostat control (C) to desired setting.
3. Set ignitor switch (A) to "OFF" position.
4. Push and rotate the "ELEC-OFF-GAS" control
(D) clockwise so that "ELEC" is visible on the
knob. Upon release, note that the knob moves
toward you, indicating that the control is locked
into electric operation.
Start-Up Instructions: DC Electric Opera-
tion - 3-Way models
1. Make certain that 12 Volts DC is available
to the refrigerator, divider switch is in NOR-
MAL position, and "GAS IGNITOR" switch
(A) is "OFF".
2. Set thermostat control (C) to desired setting.
3. Set "AC-STDBY-DC" switch (E) to "DC" posi-
tion.
4. Set ignitor switch (A) to "OFF" position.
5. Push and rotate the "ELEC-OFF-GAS" control
(D) clockwise so that "ELEC" is visible on the
knob. Upon release, note that the knob moves
toward you, indicating that the control is locked
into electric operation.
Operation Shut-Down: All Modes
1. Set ignitor switch (A) to "OFF" position.
2. Push and turn "ELEC-OFF-GAS" control (D)
to "OFF". 
3. For longer periods of shut-down, set NORMAL-
STORAGE-HUMIDITY switch to STORAGE.
Operation Note: Use the "ELEC-OFF-GAS" control
(C) to shut off all cooling operation (both Gas and
Electric). The "GAS IGNITOR" switch and the "NOR-
MAL-STORAGE-HUMIDITY" switch must be shut off
independently. The "STDBY" position of the "AC-
STDBY-DC" switch (E) can be used to temporarily
shut off AC or DC operation.