Справочник Пользователя для Master Bilt 80

Скачать
Страница из 17
 
 
 
 
 
 
 
 
MASTER-BILT ELECTRONIC REFRIGERATION CONTROL 
 
 
 
 
 
 
 
 
 
 
 
 
                                   Display Lay-out 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Compressor 
When power is first turned on to the control, the LED indicator for the Thermostat output will go through 
the start-up delay. After a one-minute delay the compressor comes on. The LED indicator stays on while compressor 
relay is energized. Display will show actual box temperature. Picture above is the display layout. The compressor will be 
cycled off when the actual box temperature reaches its set point.  The Thermostat output indicator will be off. 
 
Fan        
The  fans  will  run  constantly  for  BMG/TMG  cooler  application.    The  Evaporator  fan  will  also  cut  off  when  the 
evaporator temp is above the fan stop temperature setting.  
 
Defrost    The control uses off cycle defrost for the BMG/TMG cooler.  
 
MANUAL DEFROST 
 
Defrosting  my  also  be  induced  manually  by  keeping  the  defrost  button  for  5  seconds.    Once  defrost  has  started,  the 
defrost will go through a defrost and drip time pull down cycle.