Справочник Пользователя для Carrier 30XW325-400
12
Dimensions
30XW UNIT DIMENSIONS
30XW UNIT AND WATERBOX DIMENSIONS
NOTES:
1.
Operating weight includes weight of water, refrigerent, and oil.
2.
Denotes center of gravity.
3.
Dimensions shown in ft-in. [mm] unless noted.
4.
The recommended service clearance around the machine is 3 ft [914.4 mm].
5.
Victaulic nozzles are standard on all units. A flow switch can be factory-installed in evaporator inlet victaulic nozzle.
6.
Maximum fluid side pressure of condenser or evaporator is 150 psig [1034 kPa] (standard) or 300 psig [2068 kPa] (optional).
7.
Operating weight includes weight of water, refrigerant, and oil.
CONNECTIONS
PASSES
WATERBOX
(EVAP/COND)
NOZZLE
TYPE
D
ft-in. [mm]
E
ft-in. [mm]
F
ft-in. [mm]
MAX UNIT OPERATING WEIGHT lb [kg]
325
325
350
400
Same Ends
2 Pass
NIH/NIH
Victaulic
13-3
3
/
4
[4057]
3-11
3
/
8
[1210]
6-6
11
/
16
[1999]
14,319 [6495]
14,515 [6495]
14,759 [6695]
Flange
13-9
1
/
16
[4193]
14,651 [6646]
14,847 [6646]
15,091 [6845]
NIH/MWB
Victaulic
13-11
5
/
8
[4258]
14,498 [6576]
14,694 [6576]
14,938 [6776]
Flange
14,739 [6685]
14,935 [6685]
15,179 [6885]
MWB/NIH
Victaulic
14,489 [6572]
14,685 [6572]
14,929 [6772]
Flange
14,746 [6689]
14,768 [6689]
15,012 [6809]
MWB/MWB
Victaulic
14,668 [6653]
14,864 [6653]
15,108 [6853]
Flange
14,834 [6729]
15,030 [6729]
15,274 [6928]
Opposite Ends
NIH/NIH
Victaulic
13-6
5
/
16
[4123]
3-11
3
/
8
[1210]
6-6
11
/
16
[1999]
14,319 [6495]
14,515 [6495]
14,759 [6695]
Flange
14-4
7
/
16
[4380]
14,651 [6646]
14,847 [6646]
15,091 [6845]
NIH/MWB
Victaulic
14-2
3
/
16
[4323]
14,498 [6576]
14,694 [6576]
14,938 [6776]
Flange
14-6
15
/
16
[4443]
14,739 [6685]
14,935 [6685]
15,179 [6885]
MWB/NIH
Victaulic
14-2
13
/
16
[4339]
14,489 [6572]
14,685 [6572]
14,929 [6772]
Flange
14-8
3
/
16
[4475]
14,746 [6689]
14,768 [6689]
15,012 [6809]
MWB/MWB
Victaulic
14-10
11
/
16
[4539]
14,668 [6653]
14,864 [6653]
15,108 [6853]
Flange
14,834 [6729]
15,030 [6729]
15,274 [6928]
1 or
3 Pass
NIH/NIH
Flange
14-5
5
/
8
[4410]
14,828 [6726]
15,024 [6726]
15,268 [6925]
NIH/MWB
Flange
14-10
11
/
16
[4539]
15,223 [6905]
14,768 [6896]
15,012 [6809]
MWB/NIH
Flange
15,244 [6915]
15,440 [6894]
15,684 [7114]
MWB/MWB
Flange
15,581 [7067]
15,777 [7063]
16,021 [7267]
SUCTION
END
END
DISCHARGE
END
END
EVAPORATOR
CONDENSER
SEE NIH CONDENSER
DETAIL FOR NOZZLE
MEASUREMENTS
DETAIL FOR NOZZLE
MEASUREMENTS
SEE NIH EVAPORATOR
DETAIL FOR NOZZLE
MEASUREMENTS
DETAIL FOR NOZZLE
MEASUREMENTS
MLV (OPTIONAL)
MLV (OPTIONAL)
a30-4745
STANDARD 30XW UNIT DIMENSIONS
NOTES:
1.
Weights shown for standard chiller (2 pass with NIH, victaulic waterboxes).
2.
See page 14 for unit mounting locations.
30XW UNIT
SIZE
OPERATING
WEIGHT, lb [kg]
MOUNTING LOCATION WEIGHT, lb [kg]
DIMENSIONS (ft-in. [mm])
1
2
3
4
A
B
C
325
14,319 [6495]
3734 [1694] 3828 [1736] 3337 [1514] 3420 [1551]
6-
3
/
8
[1837]
6-
3
/
8
[1837]
3
/
8
[9.53]
350
14,515 [6584]
3785 [1717] 3880 [1760] 3383 [1535] 3467 [1573]
6-
3
/
8
[1837]
6-
3
/
8
[1837]
3
/
8
[9.53]
400
14,759 [6695]
3848 [1745] 3946 [1790] 3439 [1560] 3526 [1599]
6-
3
/
8
[1837]
6-
3
/
8
[1837]
3
/
8
[9.53]
LEGEND
MLV
— Minimum Load Valve
MWB — Marine Waterbox
NIH
NIH
— Nozzle-In-Head
SSV