LOCATION 
The installation location must be kept free and clear of combustibles. When installing, 
never enclose the bottom of the griddle with a raised curb or other constructions that 
would obstruct flow of air into or out of the griddle. Adequate clearance for air openings 
into the combustion chamber must be provided. Make sure there is an adequate supply of 
air in the room to replace air taken out by the ventilation system. 
Do not permit air to blow directly at the griddle. Avoid open windows next to the griddle 
wherever possible. Avoid wall-type fans which create air cross-currents within the room. 
This griddle is Design Certified for installation on a non-combustible counter with 4” legs, 
or combustible floor with 25” high stand. 
INSTALLATION CLEARANCES 
 
COMBUSTIBLE 
CONSTRUCTION 
NON-
COMBUSTIBLE 
CONSTRUCTION 
Back: 6” 
0” 
Right Side: 
6” 
0” 
Left Side 
6” 
0” 
 
INSTALLATION CODES AND STANDARDS 
The griddle must be installed in accordance with: 
In the United States of America: 
1.  State and local codes. 
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but 
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained 
from The American Gas Association Accredited Standards Committee Z223,  @ 400 
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 
1 Batterymarch Park Quincy, MA 02169-7471  
3.  NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available 
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 
In Canada: 
1. Local codes. 
2.  CAN/CSA-B149.1 Natural Gas Installation (latest edition)   
3.  CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the 
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3