GRIDDLES MOUNTED ON STANDS WITH CASTERS 
Griddles mounted on stands with casters must use a 
flexible connector (not supplied) that complies with the 
Standard for Connectors for Movable Gas Appliances 
ANSI Z21.69•CSA6.16, and a quick-disconnect device 
that complies with Gas Fuel, ANSI Z21.3•CSA6.9. In 
addition, adequate means must be provided to limit 
movement of the appliance without depending on the 
connector and the quick-disconnect device (or its 
associated piping) to limit appliance movement. Attach 
the restraining device at the rear of the griddle as 
shown in Fig. 1. 
Fig. 1. 
If disconnection of the restraint is necessary, turn off the gas supply before 
disconnecting. Reconnect the restraint prior to turning the gas supply on and returning 
the griddle to its installation position. 
Note: Casters are only supplied on a griddle stand. If the griddle is moved for any reason 
the griddle should be re-leveled (see LEVELING in this manual). 
STANDS 
The griddle has an optional 25” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide 
stainless steel stand with casters. The two front casters lock. The stand includes a top 
shelf with marine edges style lip and a lower shelf. 
 
CUTTING BOARDS 
Refer to the installation instructions provided with the cutting board kit. 
 
GAS CONNECTIONS 
CAUTION: Gas supply connections and any pipe joint compound must be resistant 
to the action of propane gases. 
Use a ¾” NPT gas supply line for the griddle inlet, located at the rear of the griddle. All of 
flexible and semi-rigid gas supply lines must comply with the applicable ANSI standard. 
To ensure maximum operating efficiency this appliance must be connected with a gas 
supply line of solid pipe or a commercial type Flexible Connector with the net inside 
diameter (I.D.) as large as or larger than the gas pipe inlet on this appliance. Codes 
require that a gas shutoff valve must be installed in the gas line upstream of the griddle. 
WARNING: PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR 
LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME. 
After checking for leaks all lines receiving gas should be fully purged to remove air. 
- 5 -