TROUBLE SHOOTING GUIDE
Following the procedure below to check if the oven is defective or not.
1) Check earthing before trouble checking.
2) Be careful  of the high voltage  circuit.
3) Discharge  the   high voltage  capacitor.
4) W hen checking the continuity of the switches, fuse or high voltage transform er, disconnect one lead wire from these parts
and check continuity with the AC plug removed. To do otherwise m ay result in a false reading or dam age to your meter.
(TROUBLE 1) O ven does not operate at all : any inputs can not be accepted.
NOTE
W hen electric parts are checked, be sure the pow er cord is not inserted the w all outlet.
C heck w ire harness, w iring and connected of the term inals and power cord before check the parts listed below.
CHECK
RESULT
CAUSE
REM EDY
F use blow s.
C ontinuity
N o C ontinuity
C ontinuity
0
 
infinite
Ω
 
or
A pprox. 
150~310
(norm al)
R eplace
N O T E   1
R eplace
N O T E   1
R eplace
R eplace
C heck co ntinuity of
prim ary w inding of low
voltage transform er
M alfunction
of interlock
m on itor
sw itch
D efective   low
voltage
transform er
C heck co ntinuity of
interlock  m onitor sw itch
w ith door closed
(C O M   
N C)
C heck co ntinuity of prim ary
interlock  sw itch contact
w ith door partially  open
until interlock  m onitor  switch
contact clos e
(C O M <->N O )
S horted contacts
of prim a ry
interlock sw itch.
F use again
blows
D isconne ct high voltage
fuse and  operate the unit
D efective  high
voltage transform er
C O N D IT IO N
N o C ontinuity
R eplace
N O T E   1
C heck co ntinuity of both
prim ary and  secondary
interlock sw itch w ith door
colosed
M alfunction of
interlock sw itch
N o C ontinuity
C ontinuity