Справочник Пользователя для Middleby Marshall P/N 60250

Скачать
Страница из 36
19
P/N 60250 September 28, 2012
F.  Adjusting the Minimum Pressure Setting
1.  Disconnect pressure feedback connection (if appcable).
2.  Connect a suitable pressure gauge to pipe line or to outlet 
pressure tap of gas control concerned, to measure burner 
pressure (measuring point must be as near to burner as 
possible).
3.  Disconnect electrical connection of the Moduplus
®
.
4.  Energize operator, set control in operation and wait until 
an outlet pressure is recorded on pressure gauge.
5.  If minimum rate pressure needs adjustment, use a 5 mm 
wrench to turn adjustment screw for minimum pressure 
setting  (clockwise  to  increase  or  counter-clockwise  to 
decrease  pressure),  until  the  desired  minimum  outlet 
pressure is obtained.
6.  Check if main burner lights easily and reliable at minimum 
pressure.
7.  Reconnect pressure feedback connection (if appcable).
8.  Close pressure tap screw.
G. Checkout
After any adjustment, set appliance in operation and observe 
through a component cycle to ensure that burner system com-
ponents function correctly.
NOTE:  The installer MUST verify oven operation prior to put-
ting oven into service.
H.   Maintenance
It is recommended to check yearly the minimum and the maxi-
mum setting and readjust them if necessary.
Figure 2-20.  Burner Assembly
Figure 2-21.  Gas Valve
Adjustment Screw (5 mm) 
for minimum pressure  
setting
Adjustment Screw 
(8 mm) for maxi-
mum  
pressure  
setting