Справочник Пользователя для Hotpoint SQ102PI

Скачать
Страница из 16
3
GB
TABLE OF CHARACTERISTICS
 
Dimensions
 
width 43.5 cm 
height 32 cm 
depth 40 cm
 
Volume
 
56 l
 
Electrical 
connections
 
voltage: 220-240V ~ 50Hz 
maximum power absorbed 
2800 W
 
ENERGY LABEL
 
Directive 2002/40/EC on the 
label of electric ovens. 
Regulation EN 50304  
 
Declared energy 
consumption for Forced 
convection Class  
– heating mode:          Gratin 
 
This appliance conforms to 
the following European 
Economic Community 
directives: 73/23/EEC dated 
19/02/73 (Low Voltage) and 
subsequent amendments - 
89/336/EEC dated 03/05/89 
(Electromagnetic 
Compatibility) and 
subsequent amendments - 
93/68/EEC dated 22/07/93 
and subsequent 
amendments.
 
2002/96/EEC
 
 
Electrical Connection
Electrical  connection
The electrical connection to the mains must be made
on the appliance.  The power voltage and frequency
are as indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
• Using a screwdriver, press on the tabs situated
on each side of the terminal board cover.
• Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
_ Unscrew the cable clamp screw and the contact
screws L-N-$.
• Fasten the wires beneath the screwheads using
the following colour scheme: Blue (N) Brown (L)
Yellow-Green $
• Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical  Connection:
Voltage Frequency: 230
V-1+N  50Hz
Fuse Section: 16A
Supply  cable:
3x1.5mm
2
You can connect your oven to the system means of
a terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar  circuit  breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of
its recess in the event of maintenance operations
(only use HAR - H 05 - RRF quality cables fitted with
a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unplug  the  appliance  before  all  operations,  even
when  replacing  the  oven  lamp.
Using the appliance without correct earthing is
highly  dangerous.
! After connecting the appliance to the flexible
cable, tighten all the screws on the terminal
board.
4
2
N
L