Справочник Пользователя для Southbend SSB-32

Скачать
Страница из 20
O
PERATION
 
R
ADIANT 
S
TEAKHOUSE 
B
ROILER
 
P
AGE 
8
 OF 
20 O
WNER
M
ANUAL 
1190950
 
(02/09) 
 
 
 
Figure 3
    
Broiler Controls and Components 
Removable
Grease Chute
Pilot Adjustment
Access Hole
Removable
Heavy-Duty
Broil Rack
Removable
Stainless Steel
Drip Pan
Removable
Grease Drawer
Variable High-Low-Off
Independent Gas
Adjustment
Release Paddle
Nine-Position Rack
Adjustment Arm
Gas Regulator with
1" Rear Connection
Flue Vent Chamber
 
Keep the drip pans in place below the rack when broiling!  Without them in place,  
excessive air will be pulled past the burners, reducing temperature and cooking efficiency. 
 
L
IGHTING 
A
FTER 
G
AS 
H
AS 
B
EEN 
S
HUT 
O
FF
 
When turning on the main gas supply to an appliance or a group of appliances, do the following: 
1.  Make sure that all the control valves and power switches of all the appliances are in the OFF position. 
2.  Turn on the main gas supply valve. 
3.  Light the standing pilots of each connected appliance. 
L
IGHTING 
B
ROILER 
P
ILOTS
 
The pilots should burn continuously unless the broiler is to be completely shut down. The broiler cavity has two or 
three pilots, one near each burner. If the pilots are extinguished, the pilot gas supply is NOT automatically interrupted. 
To light the pilots, do the following: 
1.  Turn the control valves on the front of the broiler to OFF. 
2.  Turn on the gas supply to the broiler (if not already on). 
3.  Light the pilots. 
S
HUTDOWN OF 
B
ROILER
 
To place the broiler in a standby state (ready for use), turn the burner control valves to OFF. The pilots will remain lit. 
To completely shut down the broiler for an extended period (or prior to disconnecting the gas supply), turn OFF the 
manual shutoff valves of all gas supply connections. (This will extinguish all pilots.)