Листовка для Philips SORA-5

Скачать
Страница из 2
Job Information 
Type:
"JSQPSU3PBE 'BMM3JWFS ."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #
Lighting Systems
 SORA-5
1BHFPG
-JHIU51FS'PPU /PNJOBM 4FDUJPO
80%
70%
50%
70 50
30
70
50
30
50 30 10
0
80 80
80
71
71
71
54 54 54
1
71 66
63
62
59
56
44 42 40
2
63 57
52
45
50
46
38 35 32
3
57 49
43
50
44
38
33 29 26
4
52 43
37
46
38
33
29 25 21
5
48 38
32
42
34
28
25 21 18
6
44 34
27
38
30
24
23 18 15
7
40 30
24
35
27
21
20 16 13
8
37 27
21
33
24
19
18 14 12
9
34 25
19
30
22
17
17 13 10
10
32 23
17
28
20
15
15 12 9
CANDLEPOWER
ZONE
0
22
45
67
90
DEG.
CANDELAS
180
563 563 563 563 563
175
564 564 563 561 560
165
548 549 552 554 553
155
537 538 527 511 506
145
554 546 503 448 442
135
556 535 480 1264 1299
125
546 519 1087 1754 1968
115
515 701 1546 1991 2106
105
438 852 1488 1770 1851
95
156 645 873 975 986
90
2 221 406 484 516
85
23 216 402 495 525
75
73 198 412 521 552
65
107 183 350 470 511
55
134 172 288 384 421
45
156 179 245 311 338
35
182 193 222 261 279
25
204 209 223 238 243
15
216 218 222 227 229
5
222 222 222 222 221
0
221 221 221 221 221
Performance
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
REPORT NO.: ITL54090
LAMPS: 2-F54T5
LUMENS: 5000
EFFICIENCY: 78.9%
CAT NO.: S254CW4WH
CANDLEPOWER CURVE
WALL REFLECTANCE
Fixture Lengths & Mounting Locations
51-5/8”
Mounting Accessories
Power Feed Cable End Set
Distance is from the ceiling
line to the top of the lumi-
naire housing.
36” Platinum: SECW36SC
36” White: SECW36WH
Stem End Set
Distance is from the ceiling
line to the top of the lumi-
naire housing.
30” Platinum: SESW3ØSC
30” White: SESW3ØWH
Intermediate Cable
Distance is from the ceiling
line to the top of the lumi-
naire housing.
36” Platinum: SICW36SC
36” White: SICW36WH
Notes:
1. Suspended wing luminaires can be continuously row mounted longer 
than 8’ (243.84cm) (but all fixtures must be 4-foot nominal units).
2. The electrical capacity of power cords cannot be exceeded.
3. Non-wing luminaires can be added to the continuous rows if desired 
Consult factory for details.
4. 30” (76.20cm) is the minimum recommended mounting distance
when designing with Wing luminaires.
Intermediate Stem
Distance is from the ceiling 
line to the top of the lumi-
naire housing.
30” Platinum: SISW3ØSC
30” White: SISW3ØWH
Intermediate Cable/Cord
Distance is from the ceiling
line to the top of the lumi-
naire housing.
36” Platinum: SIPW36SC
36” White: SIPW36WH
4-foot
8-foot
20% FLOOR CAVITY REFLECTANCE
DISTRIBUTION
Zone
Lumens
% Lamp %  Luminaire
0-90
1855
18.5
23.5
90-180
6032
60.3
76.5
0-180
7887
78.9
100.0
52-1/4” 
51-5/8”
103-3/4” 
51-5/8”