Troubleshooting & Diagnostics 
Module Status Lights 
 
 
 
44 
 
 
 
 
 
 
 
Troubleshooting
 
Figure 23. DDS Tape Module Front Panel 
 
1 - Cartridge Slot 
3 - Clean Light 
2 - Tape Light 
4 - Cartridge Unload Button 
 
Table 9. DDS Tape Module Status Light Indications 
Tape Light 
Clean Light 
Indication/ Recommended Action 
Off 
Off 
No power, tape module failed, or self-test passed. 
Check storage system power. If power is present and 
self-test passed, no action is required. If the tape 
module failed, replace the tape module. 
Flashing Green 
(1 flash/second) 
Off 
Tape loading or unloading or tape self-test is running. 
No action required. 
Flashing Green 
(2 flashes/second) 
Off 
Tape loaded and read/write activity. No action required. 
Green 
Off 
Tape loaded. Tape module ready. 
Amber or Green 
Flashing Amber 
(1 flash/second) 
Tape heads are dirty. Copy the data to a new tape, 
discard the old tape, and clean the tape heads. See 
Chapter 3 for detailed cleaning instructions. 
Amber or Green 
Amber 
Drive fault. Replace the tape module.