Справочник Пользователя для DELL E10J

Скачать
Страница из 42
Figure 13. Rear View of the Enclosure Showing the Failed Cooling Fan
Replacing a Power Supply/Cooling Fan Module
Use this procedure to replace a failed power supply/cooling fan module.
Prerequisites
1.
Use SupportAssist to send diagnostic data to Dell Technical Support Services.
About this task
You can replace power supply/cooling fan modules one at a time without shutting down the storage 
system.
Steps
1.
Press the power switch on the power supply/cooling fan module to turn it off.
2. Remove the hook-and-loop strap that secures the power cable and disconnect the power cable 
from the power supply/cooling fan module.
3. Push the release tab on the power supply/cooling fan module and slide it out of the chassis using the 
handle.
CAUTION: The power supply/cooling fan modules are heavy. To avoid injury, use both hands 
while removing the module.
Replacing SCv2000/SCv2020 Components
23