TROUBLESHOOTING AND MAINTENANCE
76
6
Close the front cover and 
then the side cover by 
pressing the round 
projections near the side 
cover open button. The error 
indicator will go out and the 
ready indicator will light up.
7
SCAN HEAD LOCKING SWITCH
The scan head locking switch is under the original table. If the switch is locked (
)
the machine will not operate. Unlock the switch (
) as shown below.
To lock the scan head locking switch, hold up the catch in illustration 
 and turn the 
center knob counter-clockwise 90 degrees until you hear a click.
When closing the covers, be sure to close the front cover securely and 
then close the side cover. If the covers are closed in the wrong order, 
the covers may be damaged.
Even after a new toner cartridge is installed, the start (
) indicator 
may not light up, indicating copying cannot be restarted (toner is not 
sufficiently fed). In this case, open and close the side cover. The copier 
will feed toner again approximately 2 minutes and then copying can be 
restarted.
Caution
Note
Lock
Unlock
Grasp here and turn in 
the direction of the arrow.
A
A