A-61662   October 2011
4-15
Resetting the maintenance reminders
If a maintenance interval expires triggering the maintenance reminder, 
a hyperlink for that component will navigate you to reset and restart the 
interval count. This process is necessary to ensure required 
maintenance continues to be monitored appropriately.
NOTE: The alert intervals for calibrating the front and back cameras 
cannot be adjusted. If an alert to calibrate the camera(s) is 
displayed, click the corresponding hyperlink to perform the 
calibration procedure. For procedures on calibrating the 
cameras, see Chapter 6, Maintenance.
Settings button
When you click the Settings button on the Ngenuity Operator Utility 
main screen, the Configure Scanner Settings screen will be displayed.
You can configure basic scanner settings using this screen.
Sleep timeout — you can set the delay time in hours and minutes that 
the scanner can be idle with full power before going into sleep mode. 
The default timeout is 15 minutes; the maximum time is 4 hours.
NOTE: Sleep mode can also be entered manually by pressing the 
Pause/Stop button on the control panel. See the section 
entitled, “Batch Control” earlier in this chapter for more 
information.
Multifeed — allows you to adjust the sensitivity when scanning Normal 
or Very thin documents. 
• Normal: for documents that range from thick card stock to thin 
carbon copies. This setting should be used for most documents.
• Very thin: used to detect multifeeds when scanning ultra-thin 
documents such as rice paper.